Back to the list of connectors

HP BladeSystem (SNMP)

Description

This connector provides hardware monitoring for the HP BladeSystem racks through the HP Insight Management Agents.

Connector ID: HPBladeSystem

This connector is superseded by:

Target

Typical platform: HP BladeSystem

Operating systems: Out-of-Band, Microsoft Windows, Linux, Oracle Solaris

Prerequisites

Leverages: HP iLO / HP Insight Management Agents

Technology and protocols: SNMP

Examples

CLI

hws HOSTNAME -t management -f HPBladeSystem --snmp v2c --community public

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: management
  selectedConnectors: [ HPBladeSystem ] # Optional, to load only this connector
  snmp:
    version: v1 # Read documentation for v2 and v3
    community: public # or probably something more secure

Connector Activation Criteria

The HP BladeSystem (SNMP) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.232.22.2.3.1.1.1.1 must return a value in the same subtree

Metrics

Type Collected Metrics Specific Attributes (Labels)
Enclosure
  • hw.enclosure.energy
  • hw.status{hw.type="enclosure",state="ok|degraded|failed"}
  • hw.status{hw.type="enclosure",state="present"}
  • info
  • model
  • serial_number
  • type
  • vendor
Blade
  • hw.blade.power_state{state="on|off|suspended"}
  • hw.status{hw.type="blade",state="ok|degraded|failed"}
  • hw.status{hw.type="blade",state="present"}
  • model
  • blade_name
  • serial_number
Fan
  • hw.status{hw.type="fan",state="ok|degraded|failed"}
  • hw.status{hw.type="fan",state="present"}
  • sensor_location
Other Device
  • hw.status{hw.type="other_device",state="ok|degraded|failed"}
  • hw.status{hw.type="other_device",state="present"}
  • device_type
Power Supply
  • hw.power_supply.limit{limit_type="max"}
  • hw.status{hw.type="power_supply",state="ok|degraded|failed"}
  • hw.status{hw.type="power_supply",state="present"}
    Temperature Sensor
    • hw.status{hw.type="temperature",state="ok|degraded|failed"}
    • hw.status{hw.type="temperature",state="present"}
    • hw.temperature
    • hw.temperature.limit{limit_type="high.degraded"}
    • sensor_location
    No results.