Back to the list of connectors
HP BladeSystem (SNMP)
Description
This connector provides hardware monitoring for the HP BladeSystem racks through the HP Insight Management Agents.
Connector ID: HPBladeSystem
This connector is superseded by:
Target
Typical platform: HP BladeSystem
Operating systems: Out-of-Band, Microsoft Windows, Linux, Oracle Solaris
Prerequisites
Leverages: HP iLO / HP Insight Management Agents
Technology and protocols: SNMP
Examples
CLI
hws HOSTNAME -t management -f HPBladeSystem --snmp v2c --community public
hws-config.yaml
hosts:
- host:
hostname: <HOSTNAME> # Change with actual host name
type: management
selectedConnectors: [ HPBladeSystem ] # Optional, to load only this connector
snmp:
version: v1 # Read documentation for v2 and v3
community: public # or probably something more secure
Connector Activation Criteria
The HP BladeSystem (SNMP) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- An SNMP Get-Next on the OID
1.3.6.1.4.1.232.22.2.3.1.1.1.1
must return a value in the same subtree
Metrics
Type | Collected Metrics | Specific Attributes (Labels) |
---|---|---|
Enclosure |
|
|
Blade |
|
|
Fan |
|
|
Other Device |
|
|
Power Supply |
|
|
Temperature Sensor |
|
|
Search Results for {{siteSearch | truncate:'50'}}
{{resultArray.length}}
No results.