Back to the list of connectors
HP iLO Gen 10 (REST)
Description
This connector discovers the status of an HPE Proliant Gen 10 system using iLO 5, as well as the various environment sensors (temperatures, fans, power supplies, etc.). Requires iLO 5.
Connector ID: HPEGen10IloREST
This connector supersedes:
Target
Typical platform: HP iLO Gen 10 REST
Operating system: Out-of-Band
Prerequisites
Leverages:
Technology and protocols: HTTP/REST
This connector is not available for the local host (it is applicable to remote hosts only).
Examples
CLI
hws HOSTNAME -t management -f HPEGen10IloREST --https --http-port 443 -u USERNAME
hws-config.yaml
hosts:
- host:
hostname: <HOSTNAME> # Change with actual host name
type: management
selectedConnectors: [ HPEGen10IloREST ] # Optional, to load only this connector
http:
https: true
port: 443 # or probably something else
username: <USERNAME> # Change with actual credentials
password: <PASSWORD> # Encrypted using hws-encrypt
Connector Activation Criteria
The HP iLO Gen 10 (REST) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- The HTTP Request below to the managed host succeeds:
- GET
/redfish/v1/
- Request Header:
EmbeddedFile(1)
- The response body contains:
iLO 5
(regex)
- GET
Metrics
Type | Collected Metrics | Specific Attributes (Labels) |
---|---|---|
Enclosure |
|
|
Disk Controller |
|
|
Battery |
|
|
Processor |
|
|
Fan |
|
|
Logical Disk, RAID |
|
|
Memory Module |
|
|
Network Card, FC Port |
|
|
Physical Disk |
|
|
Power Supply |
|
|
Temperature Sensor |
|
|
Search Results for {{siteSearch | truncate:'50'}}
{{resultArray.length}}