Back to the list of connectors
HP iLO Gen 9 (REST)
Description
This connector discovers the status of an HPE Proliant Gen 9 system using iLO 4, as well as the various environment sensors (temperatures, fans, power supplies, etc.). Requires iLO 4.
Connector ID: HPEGen9IloREST
This connector supersedes:
Target
Typical platform: HP iLO Gen 9 REST
Operating system: Out-of-Band
Prerequisites
Leverages:
Technology and protocols: HTTP/REST
This connector is not available for the local host (it is applicable to remote hosts only).
Examples
CLI
hws HOSTNAME -t management -f HPEGen9IloREST --https --http-port 443 -u USERNAME
hws-config.yaml
hosts:
- host:
hostname: <HOSTNAME> # Change with actual host name
type: management
selectedConnectors: [ HPEGen9IloREST ] # Optional, to load only this connector
http:
https: true
port: 443 # or probably something else
username: <USERNAME> # Change with actual credentials
password: <PASSWORD> # Encrypted using hws-encrypt
Connector Activation Criteria
The HP iLO Gen 9 (REST) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- The HTTP Request below to the managed host succeeds:
- GET
/redfish/v1/
- Request Header:
EmbeddedFile(1)
- The response body contains:
iLO 4
(regex)
- GET
Metrics
Type | Collected Metrics | Specific Attributes (Labels) |
---|---|---|
Enclosure |
|
|
Disk Controller |
|
|
Battery |
|
|
Processor |
|
|
Fan |
|
|
Logical Disk, RAID |
|
|
Memory Module |
|
|
Network Card, FC Port |
|
|
Physical Disk |
|
|
Power Supply |
|
|
Temperature Sensor |
|
|