Back to the list of connectors

HP P2000 G3 or Later (WBEM)

Description

This connector discovers the Environmental, Physical Disk, Logical Disk, Management Network Cards and Fibre Ports on P2000 G3 later Series Filers through the Embedded SMI-S Provider

Connector ID: HPP2000WBEM

This connector supersedes:

Target

Typical platform: HP StorageWorks P2000 G3

Operating system: Storage System

Prerequisites

Leverages: HP P2000 Management Card

Technology and protocols: WBEM

This connector is not available for the local host (it is applicable to remote hosts only).

Examples

CLI

hws HOSTNAME -t storage -f HPP2000WBEM --wbem -u USER

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: storage
  selectedConnectors: [ HPP2000WBEM ] # Optional, to load only this connector
  wbem:
    protocol: https
    port: 5989
    username: <USERNAME> # Change with actual credentials
    password: <PASSWORD> # Encrypted using hws-encrypt

Connector Activation Criteria

The HP P2000 G3 or Later (WBEM) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • The WBEM query below to the managed host succeeds:
    • Namespace: root/hpq
    • WQL Query: SELECT Name FROM HP_TopComputerSystem
  • The WBEM query below to the managed host succeeds:
    • Namespace: root/hpq
    • WQL Query: SELECT Tag FROM HP_TopComputerSystemChassis

Metrics

Type Collected Metrics Specific Attributes (Labels)
Enclosure
  • hw.status{hw.type="enclosure",state="ok|degraded|failed"}
  • hw.status{hw.type="enclosure",state="present"}
  • info
  • model
  • serial_number
  • type
  • vendor
Fan
  • hw.status{hw.type="fan",state="ok|degraded|failed"}
  • hw.status{hw.type="fan",state="present"}
    Logical Disk, RAID
    • hw.logical_disk.limit
    • hw.status{hw.type="logical_disk",state="ok|degraded|failed"}
    • hw.status{hw.type="logical_disk",state="present"}
      Network Card, FC Port
      • hw.network.bandwidth.limit
      • hw.network.up
      • hw.status{hw.type="network",state="ok|degraded|failed"}
      • hw.status{hw.type="network",state="present"}
      • physical_address
      Other Device
      • hw.status{hw.type="other_device",state="ok|degraded|failed"}
      • hw.status{hw.type="other_device",state="present"}
      • device_type
      Physical Disk
      • hw.physical_disk.size
      • hw.status{hw.type="physical_disk",state="ok|degraded|failed"}
      • hw.status{hw.type="physical_disk",state="present"}
      • info
      • model
      • serial_number
      Power Supply
      • hw.status{hw.type="power_supply",state="ok|degraded|failed"}
      • hw.status{hw.type="power_supply",state="present"}
        Temperature Sensor
        • hw.status{hw.type="temperature",state="ok|degraded|failed"}
        • hw.status{hw.type="temperature",state="present"}
          Voltage Sensor
          • hw.status{hw.type="voltage",state="ok|degraded|failed"}
          • hw.status{hw.type="voltage",state="present"}
            No results.