Back to the list of connectors
HP-UX - Smart Array RAID
Description
Display the physical disks connected to a Smart Array Controller and any configured logical drive and spare drive.
Connector ID: HPUXSAUtil
This connector is superseded by:
Target
Typical platforms: HP 9000, HP Integrity, HP SuperDome
Operating system: HP-UX
Prerequisites
Leverages: HP-UX Smart Array Configuration Utility
Technology and protocols: System Commands
This connector requires advanced privileges on the managed host for the command below:
/opt/raidsa/bin/sautil
This connector therefore needs to run as root or you need to configure a privilege-escalation mechanism like sudo
on the managed host to allow the monitoring account to run the command listed above.
Sample of /etc/sudoers to allow the above command to be run as root by the hwsagent account:
hwsagent ALL=(root) NOPASSWD: /opt/raidsa/bin/sautil
Examples
CLI
hws HOSTNAME -t hp -f HPUXSAUtil --ssh -u USER --sudo-command-list /opt/raidsa/bin/sautil
hws-config.yaml
hosts:
- host:
hostname: <HOSTNAME> # Change with actual host name
type: hp
selectedConnectors: [ HPUXSAUtil ] # Optional, to load only this connector
ssh:
username: <USERNAME> # Change with actual credentials
password: <PASSWORD> # Encrypted using hws-encrypt
useSudo: true
useSudoCommands: [ "/opt/raidsa/bin/sautil" ]
Connector Activation Criteria
The HP-UX - Smart Array RAID connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- Operating System is HP-UX
- The command below succeeds on the monitored host
- Command:
ls /opt/raidsa/bin/sautil
- Output contains:
sautil$
(regex)
- Command:
- The command below succeeds on the monitored host
- Command:
/bin/sh %EmbeddedFile(1)%
- Output contains:
[GgTtMm][Bb]
(regex)
- Command:
Metrics
Type | Collected Metrics | Specific Attributes (Labels) |
---|---|---|
Disk Controller |
|
|
Battery |
|
|
Logical Disk, RAID |
|
|
Physical Disk |
|
|