Back to the list of connectors
HP-UX - sasmgr Disk Controllers
Description
Provides hardware SAS RAID disks status information on HP-UX systems. Requires root privileges.
Connector ID: HPUXSasMgr
This connector is superseded by:
Target
Typical platforms: HP 9000, HP Integrity, HP SuperDome
Operating system: HP-UX
Prerequisites
Leverages: HP-UX system commands (sasmgr, ioscan etc.)
Technology and protocols: System Commands
This connector requires advanced privileges on the managed host for the command below:
- /opt/sas/bin/sasmgr
This connector therefore needs to run as root or you need to configure a privilege-escalation mechanism like sudo on the managed host to allow the monitoring account to run the command listed above.
Sample of /etc/sudoers to allow the above command to be run as root by the hwsagent account:
hwsagent ALL=(root) NOPASSWD: /opt/sas/bin/sasmgr
Examples
CLI
hws HOSTNAME -t hp -f HPUXSasMgr --ssh -u USER --sudo-command-list /opt/sas/bin/sasmgrhws-config.yaml
hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: hp
  selectedConnectors: [ HPUXSasMgr ] # Optional, to load only this connector
  ssh:
    username: <USERNAME> # Change with actual credentials
    password: <PASSWORD> # Encrypted using hws-encrypt
    useSudo: true
    useSudoCommands: [ "/opt/sas/bin/sasmgr" ]
Connector Activation Criteria
The HP-UX - sasmgr Disk Controllers connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- Operating System is HP-UX
- The command below succeeds on the monitored host 
    - Command: /bin/ls /opt/sas/bin/sasmgr
- Output contains: sasmgr$(regex)
 
- Command: 
- The command below succeeds on the monitored host 
    - Command: /bin/sh %EmbeddedFile(1)%
- Output contains: Info for PHY ID(regex)
 
- Command: 
Metrics
| Type | Collected Metrics | Specific Attributes (Labels) | 
|---|---|---|
| Disk Controller | 
 | 
 | 
| Logical Disk, RAID | 
 | 
 | 
| Physical Disk | 
 |  |