Back to the list of connectors
Hitachi Compute Blade Chassis
Description
This connector provides hardware monitoring for the Hitachi Compute Blade series chassis through the Hitachi Compute Blades Management Module
Connector ID: HitachiComputeBlade
Target
Typical platform: Hitachi Compute Blade
Operating system: Out-of-Band
Prerequisites
Leverages: Hitachi Compute Blade Chassis Management Module
Technology and protocols: SNMP
Examples
CLI
hws HOSTNAME -t management -f HitachiComputeBlade --snmp v2c --community public
hws-config.yaml
hosts:
- host:
hostname: <HOSTNAME> # Change with actual host name
type: management
selectedConnectors: [ HitachiComputeBlade ] # Optional, to load only this connector
snmp:
version: v1 # Read documentation for v2 and v3
community: public # or probably something more secure
Connector Activation Criteria
The Hitachi Compute Blade Chassis connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- An SNMP Get-Next on the OID
1.3.6.1.4.1.116.5.52.1.1.1
must return a value in the same subtree
Metrics
Type | Collected Metrics | Specific Attributes (Labels) |
---|---|---|
Enclosure |
|
|
Blade |
|
|
Fan |
|
|
Other Device |
|
|
Power Supply |
|
|
Temperature Sensor |
|
|
Voltage Sensor |
|
|