Back to the list of connectors

Hitachi Compute Blade Chassis

Description

This connector provides hardware monitoring for the Hitachi Compute Blade series chassis through the Hitachi Compute Blades Management Module

Connector ID: HitachiComputeBlade

Target

Typical platform: Hitachi Compute Blade

Operating system: Out-of-Band

Prerequisites

Leverages: Hitachi Compute Blade Chassis Management Module

Technology and protocols: SNMP

Examples

CLI

hws HOSTNAME -t management -f HitachiComputeBlade --snmp v2c --community public

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: management
  selectedConnectors: [ HitachiComputeBlade ] # Optional, to load only this connector
  snmp:
    version: v1 # Read documentation for v2 and v3
    community: public # or probably something more secure

Connector Activation Criteria

The Hitachi Compute Blade Chassis connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.116.5.52.1.1.1 must return a value in the same subtree

Metrics

Type Collected Metrics Specific Attributes (Labels)
Enclosure
  • hw.enclosure.energy
  • hw.status{hw.type="enclosure",state="present"}
  • info
  • bios_version
  • model
  • serial_number
  • type
  • vendor
Blade
  • hw.blade.power_state{state="on|off|suspended"}
  • hw.status{hw.type="blade",state="ok|degraded|failed"}
  • hw.status{hw.type="blade",state="present"}
  • info
  • model
  • serial_number
Fan
  • hw.status{hw.type="fan",state="ok|degraded|failed"}
  • hw.status{hw.type="fan",state="present"}
  • sensor_location
Other Device
  • hw.status{hw.type="other_device",state="ok|degraded|failed"}
  • hw.status{hw.type="other_device",state="present"}
  • info
  • device_type
Power Supply
  • hw.status{hw.type="power_supply",state="ok|degraded|failed"}
  • hw.status{hw.type="power_supply",state="present"}
    Temperature Sensor
    • hw.status{hw.type="temperature",state="ok|degraded|failed"}
    • hw.status{hw.type="temperature",state="present"}
    • hw.temperature
      Voltage Sensor
      • hw.status{hw.type="voltage",state="ok|degraded|failed"}
      • hw.status{hw.type="voltage",state="present"}
      • hw.voltage