Back to the list of connectors

Huawei Servers - Management Card

Description

This connector provides hardware monitoring through Huawei iMana Management Card using SNMP.

Connector ID: HuaweiiMana

This connector supersedes:

Target

Typical platform: Huawei

Operating system: Out-of-Band

Prerequisites

Leverages: Huawei iMana or iBMC Management Card

Technology and protocols: SNMP

Examples

CLI

hws HOSTNAME -t management -f HuaweiiMana --snmp v2c --community public

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: management
  selectedConnectors: [ HuaweiiMana ] # Optional, to load only this connector
  snmp:
    version: v1 # Read documentation for v2 and v3
    community: public # or probably something more secure

Connector Activation Criteria

The Huawei Servers - Management Card connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.2011.2.235.1.1.15.50 must return a value in the same subtree

Metrics

Type Collected Metrics Specific Attributes (Labels)
Enclosure
  • hw.enclosure.energy
  • hw.status{hw.type="enclosure",state="ok|degraded|failed"}
  • hw.status{hw.type="enclosure",state="present"}
  • model
  • serial_number
  • type
  • vendor
Processor
  • hw.cpu.speed.limit{limit_type="max"}
  • hw.status{hw.type="cpu",state="ok|degraded|failed"}
  • hw.status{hw.type="cpu",state="present"}
  • model
  • vendor
Fan
  • hw.fan.speed
  • hw.status{hw.type="fan",state="ok|degraded|failed"}
  • hw.status{hw.type="fan",state="present"}
    Memory Module
    • hw.memory.limit
    • hw.status{hw.type="memory",state="ok|degraded|failed"}
    • hw.status{hw.type="memory",state="present"}
    • info
    • vendor
    Other Device
    • hw.status{hw.type="other_device",state="ok|degraded|failed"}
    • hw.status{hw.type="other_device",state="present"}
    • device_type
    Physical Disk
    • hw.status{hw.type="physical_disk",state="ok|degraded|failed"}
    • hw.status{hw.type="physical_disk",state="present"}
      Power Supply
      • hw.status{hw.type="power_supply",state="ok|degraded|failed"}
      • hw.status{hw.type="power_supply",state="present"}
      • info
      Temperature Sensor
      • hw.status{hw.type="temperature",state="present"}
      • hw.temperature
      • hw.temperature.limit{limit_type="high.critical"}
      • hw.temperature.limit{limit_type="high.degraded"}
        No results.