Back to the list of connectors
IBM DataPower (SNMP)
Description
This connector discovers the enclosure and the disks of IBM DataPower Appliances as well as the various environment sensors (temperatures, fans, power supplies). It relies on the SNMP protocol.
Connector ID: IBMDataPower
Target
Typical platform: IBM DataPower
Operating system: Out-of-Band
Prerequisites
Leverages: IBM DataPower SNMP Agent
Technology and protocols: SNMP
This connector is not available for the local host (it is applicable to remote hosts only).
Examples
CLI
hws HOSTNAME -t management -f IBMDataPower --snmp v2c --community public
hws-config.yaml
hosts:
- host:
hostname: <HOSTNAME> # Change with actual host name
type: management
selectedConnectors: [ IBMDataPower ] # Optional, to load only this connector
snmp:
version: v1 # Read documentation for v2 and v3
community: public # or probably something more secure
Connector Activation Criteria
The IBM DataPower (SNMP) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- An SNMP Get-Next on the OID
1.3.6.1.4.1.14685.3.1.100.1
must return a value in the same subtree
Metrics
Type | Collected Metrics | Specific Attributes (Labels) |
---|---|---|
Enclosure |
|
|
Fan |
|
|
Physical Disk |
|
|
Power Supply |
|
|
Temperature Sensor |
|
|
Voltage Sensor |
|
|