Back to the list of connectors

Intel Modular Server

Description

This connector provides hardware monitoring through the Intel Modular Server Chassis Managament Module's SNMP Agents.

Connector ID: IntelModularServer

Target

Typical platform: Intel Modular

Operating system: Out-of-Band

Prerequisites

Leverages: Intel Server Manager 8 SNMP Agents

Technology and protocols: SNMP

This connector is not available for the local host (it is applicable to remote hosts only).

Examples

CLI

hws HOSTNAME -t management -f IntelModularServer --snmp v2c --community public

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: management
  selectedConnectors: [ IntelModularServer ] # Optional, to load only this connector
  snmp:
    version: v1 # Read documentation for v2 and v3
    community: public # or probably something more secure

Connector Activation Criteria

The Intel Modular Server connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.343.2.19.1.2.10.1 must return a value in the same subtree

Metrics

Type Collected Metrics Specific Attributes (Labels)
Enclosure
  • hw.status{hw.type="enclosure",state="present"}
  • type
  • vendor
Disk Controller
  • hw.status{hw.type="disk_controller",state="ok|degraded|failed"}
  • hw.status{hw.type="disk_controller",state="present"}
  • model
Blade
  • hw.status{hw.type="blade",state="ok|degraded|failed"}
  • hw.status{hw.type="blade",state="present"}
    Fan
    • hw.fan.limit{limit_type="high.critical"}
    • hw.fan.speed
    • hw.status{hw.type="fan",state="ok|degraded|failed"}
    • hw.status{hw.type="fan",state="present"}
    • sensor_location
    Network Card, FC Port
    • hw.errors{hw.type="network"}
    • hw.network.bandwidth.limit
    • hw.network.bandwidth.utilization
    • hw.network.io{direction="receive"}
    • hw.network.io{direction="transmit"}
    • hw.network.up
    • hw.status{hw.type="network",state="ok|degraded|failed"}
    • hw.status{hw.type="network",state="present"}
    • physical_address
    Other Device
    • hw.status{hw.type="other_device",state="ok|degraded|failed"}
    • hw.status{hw.type="other_device",state="present"}
    • device_type
    Physical Disk
    • hw.physical_disk.size
    • hw.status{hw.type="physical_disk",state="ok|degraded|failed"}
    • hw.status{hw.type="physical_disk",state="predicted_failure"}
    • hw.status{hw.type="physical_disk",state="present"}
    • info
    • firmware_version
    • serial_number
    • vendor
    Power Supply
    • hw.status{hw.type="power_supply",state="ok|degraded|failed"}
    • hw.status{hw.type="power_supply",state="present"}
      No results.