Back to the list of connectors

LsiLogic MegaRAID SAS (Newer Controllers)

Description

This connector provides disk monitoring through the LsiLogic MegaRAID SAS SNMP sub-agent which supports newer LSI MegaRaid SAS RAID controllers.

Connector ID: LSIMegaRaidSAS5

This connector is superseded by:

This connector supersedes:

Target

Typical platform: Fujitsu-Siemens PRIMERGY

Operating systems: Microsoft Windows, Linux

Prerequisites

Leverages: LSI MegaRAID SAS SNMP Agent

Technology and protocols: SNMP

Examples

CLI

hws HOSTNAME -t win -f LSIMegaRaidSAS5 --snmp v2c --community public

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: win
  selectedConnectors: [ LSIMegaRaidSAS5 ] # Optional, to load only this connector
  snmp:
    version: v1 # Read documentation for v2 and v3
    community: public # or probably something more secure

Connector Activation Criteria

The LsiLogic MegaRAID SAS (Newer Controllers) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.3582.5.1.4.2.1.2.1 must return a value in the same subtree

Metrics

Type Collected Metrics Specific Attributes (Labels)
Disk Controller
  • hw.status{hw.type="disk_controller",state="present"}
  • driver_version
  • firmware_version
  • model
  • vendor
Logical Disk, RAID
  • hw.logical_disk.limit
  • hw.status{hw.type="logical_disk",state="ok|degraded|failed"}
  • hw.status{hw.type="logical_disk",state="present"}
  • raid_level
Physical Disk
  • hw.errors{hw.type="physical_disk"}
  • hw.physical_disk.size
  • hw.status{hw.type="physical_disk",state="ok|degraded|failed"}
  • hw.status{hw.type="physical_disk",state="present"}
  • vendor