Back to the list of connectors
Lenovo IMM Event Monitoring (SNMP)
Description
This connector provides hardware monitoring through Lenovo's IMM management card. It supplements the active monitoring of the Lenovo IMM connector by parsing the Event Log. This allows older IBM xSeries systems to be fully monitored via their IMM.
Connector ID: LenovoIMMEventTable
Target
Typical platform: Lenovo
Operating system: Out-of-Band
Prerequisites
Leverages: Lenovo IMM's SNMP Service
Technology and protocols: SNMP
Examples
CLI
hws HOSTNAME -t management -f LenovoIMMEventTable --snmp v2c --community public
hws-config.yaml
hosts:
- host:
hostname: <HOSTNAME> # Change with actual host name
type: management
selectedConnectors: [ LenovoIMMEventTable ] # Optional, to load only this connector
snmp:
version: v1 # Read documentation for v2 and v3
community: public # or probably something more secure
Connector Activation Criteria
The Lenovo IMM Event Monitoring (SNMP) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- An SNMP Get-Next on the OID
1.3.6.1.4.1.2.3.51.3.2.1.1.1
must return a value in the same subtree