Back to the list of connectors

NetApp E-Series

Description

This connector discovers the status of a NetApp E-Series Storage Array, including environment sensors (temperatures, fans, power supplies, etc.). Relies on NetApp SANtricity REST API

Connector ID: NetappESeries

Target

Typical platform: NetApp E-Series

Operating system: Storage System

Prerequisites

Leverages:

Technology and protocols: HTTP/REST

This connector is not available for the local host (it is applicable to remote hosts only).

Examples

CLI

hws HOSTNAME -t storage -f NetappESeries --https --http-port 443 -u USERNAME

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: storage
  selectedConnectors: [ NetappESeries ] # Optional, to load only this connector
  http:
    https: true
    port: 443 # or probably something else
    username: <USERNAME> # Change with actual credentials
    password: <PASSWORD> # Encrypted using hws-encrypt

Connector Activation Criteria

The NetApp E-Series connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • The HTTP Request below to the managed host succeeds:
    • GET /devmgr/v2/storage-systems/1
    • The response body contains: "chassisSerialNumber": (regex)

Metrics

Type Collected Metrics Specific Attributes (Labels)
Enclosure
  • hw.status{hw.type="enclosure",state="ok|degraded|failed"}
  • hw.status{hw.type="enclosure",state="present"}
  • info
  • model
  • serial_number
  • type
  • vendor
Disk Controller
  • hw.status{hw.type="disk_controller",state="ok|degraded|failed"}
  • hw.status{hw.type="disk_controller",state="present"}
  • info
  • model
  • serial_number
  • vendor
Battery
  • hw.status{hw.type="battery",state="ok|degraded|failed"}
  • hw.status{hw.type="battery",state="present"}
  • info
  • model
  • type
Fan
  • hw.status{hw.type="fan",state="ok|degraded|failed"}
  • hw.status{hw.type="fan",state="present"}
    Logical Disk, RAID
    • hw.logical_disk.limit
    • hw.status{hw.type="logical_disk",state="ok|degraded|failed"}
    • hw.status{hw.type="logical_disk",state="present"}
    • raid_level
    Memory Module
    • hw.memory.limit
    • hw.status{hw.type="memory",state="ok|degraded|failed"}
    • hw.status{hw.type="memory",state="present"}
    • model
    • serial_number
    • vendor
    Network Card, FC Port
    • hw.network.bandwidth.limit
    • hw.network.up
    • hw.status{hw.type="network",state="ok|degraded|failed"}
    • hw.status{hw.type="network",state="present"}
    • info
    • physical_address
    Other Device
    • hw.status{hw.type="other_device",state="ok|degraded|failed"}
    • hw.status{hw.type="other_device",state="present"}
    • info
    • device_type
    Physical Disk
    • hw.physical_disk.endurance_utilization{state="remaining"}
    • hw.physical_disk.size
    • hw.status{hw.type="physical_disk",state="ok|degraded|failed"}
    • hw.status{hw.type="physical_disk",state="present"}
    • info
    • firmware_version
    • model
    • serial_number
    • vendor
    Power Supply
    • hw.status{hw.type="power_supply",state="ok|degraded|failed"}
    • hw.status{hw.type="power_supply",state="present"}
    • info
    Temperature Sensor
    • hw.status{hw.type="temperature",state="ok|degraded|failed"}
    • hw.status{hw.type="temperature",state="present"}
      No results.