Back to the list of connectors
SMI-S Compliant SAN Switches
Description
This connector discovers the enclosure and fiber-channel ports of SAN switches as well as the various environment sensors (temperatures, fans, power supplies, etc.). It relies on the WBEM technology and supports SMI-S compliant switches only.
Connector ID: SMISSwitch
This connector is superseded by:
Target
Typical platform: Any SMI-S compliant SAN switch
Operating system: Storage System
Prerequisites
Leverages: SMI-S Agent provided by the switch vendor
Technology and protocols: WBEM
Examples
CLI
hws HOSTNAME -t storage -f SMISSwitch --wbem -u USER
hws-config.yaml
hosts:
- host:
hostname: <HOSTNAME> # Change with actual host name
type: storage
selectedConnectors: [ SMISSwitch ] # Optional, to load only this connector
wbem:
protocol: https
port: 5989
username: <USERNAME> # Change with actual credentials
password: <PASSWORD> # Encrypted using hws-encrypt
Connector Activation Criteria
The SMI-S Compliant SAN Switches connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- The WBEM query below to the managed host succeeds:
- Namespace:
Automatic
- WQL Query:
SELECT Dedicated FROM CIM_ComputerSystem
- Result contains:
^5|;*$
(regex)
- Namespace:
- The WBEM query below to the managed host succeeds:
- Namespace:
Automatic
- WQL Query:
SELECT PortType FROM CIM_FCPort
- Result contains:
^\(14\)\|\(15\)\|\(16\)\|\(17\)\|\(18\);$
(regex)
- Namespace:
Metrics
Type | Collected Metrics | Specific Attributes (Labels) |
---|---|---|
Enclosure |
|
|
Fan |
|
|
Network Card, FC Port |
|
|
Other Device |
|
|
Power Supply |
|
|
Temperature Sensor |
|
|
Search Results for {{siteSearch | truncate:'50'}}
{{resultArray.length}}
No results.