Back to the list of connectors

Fujitsu-Siemens Serverview

Description

This connector provides hardware monitoring through the Fujitsu-Siemens Serverview Agent which supports almost all Fujitsu-Siemens PRIMERGY servers.

Connector ID: ServerviewNT

This connector is superseded by:

This connector supersedes:

Target

Typical platform: Fujitsu-Siemens PRIMERGY

Operating systems: Microsoft Windows, Linux

Prerequisites

Leverages: Fujitsu-Siemens Serveview Agent

Technology and protocols: SNMP

Examples

CLI

hws HOSTNAME -t win -f ServerviewNT --snmp v2c --community public

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: win
  selectedConnectors: [ ServerviewNT ] # Optional, to load only this connector
  snmp:
    version: v1 # Read documentation for v2 and v3
    community: public # or probably something more secure

Connector Activation Criteria

The Fujitsu-Siemens Serverview connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.231.2.10.2 must return a value in the same subtree

Metrics

Type Collected Metrics Specific Attributes (Labels)
Enclosure
  • hw.status{hw.type="enclosure",state="open"}
  • hw.status{hw.type="enclosure",state="present"}
  • model
  • serial_number
  • type
  • vendor
Processor
  • hw.cpu.speed.limit{limit_type="max"}
  • hw.status{hw.type="cpu",state="ok|degraded|failed"}
  • hw.status{hw.type="cpu",state="present"}
  • info
  • model
  • vendor
Fan
  • hw.fan.speed
  • hw.status{hw.type="fan",state="ok|degraded|failed"}
  • hw.status{hw.type="fan",state="present"}
  • info
  • sensor_location
Memory Module
  • hw.errors{hw.type="memory"}
  • hw.memory.limit
  • hw.status{hw.type="memory",state="ok|degraded|failed"}
  • hw.status{hw.type="memory",state="present"}
  • info
  • type
Power Supply
  • hw.status{hw.type="power_supply",state="ok|degraded|failed"}
  • hw.status{hw.type="power_supply",state="present"}
  • power_supply_type
Temperature Sensor
  • hw.status{hw.type="temperature",state="present"}
  • hw.temperature
  • hw.temperature.limit{limit_type="high.critical"}
  • hw.temperature.limit{limit_type="high.degraded"}
  • sensor_location
Voltage Sensor
  • hw.status{hw.type="voltage",state="present"}
  • hw.voltage
  • hw.voltage.limit{limit_type="high.critical"}
  • hw.voltage.limit{limit_type="low.critical"}
  • sensor_location