Back to the list of connectors

MegaCLI Managed RAID Controllers

Description

Provides the monitoring of LSI RAID controllers in Oracle/Sun Solaris systems, and in IBM servers with EXP3000 external bays. This connector relies on MegaCli.

Connector ID: SunMegaCli

This connector supersedes:

Target

Typical platform: Any system with LSI MegaCli

Operating systems: Oracle Solaris, Linux

Prerequisites

Leverages: MegaCli (LSI) managed RAID card

Technology and protocols: System Commands

This connector requires advanced privileges on the managed host for the command below:

  • MegaCli

This connector therefore needs to run as root or you need to configure a privilege-escalation mechanism like sudo on the managed host to allow the monitoring account to run the command listed above.

Sample of /etc/sudoers to allow the above command to be run as root by the hwsagent account:

hwsagent ALL=(root) NOPASSWD: MegaCli

Examples

CLI

hws HOSTNAME -t solaris -f SunMegaCli --ssh -u USER --sudo-command-list MegaCli

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: solaris
  selectedConnectors: [ SunMegaCli ] # Optional, to load only this connector
  ssh:
    username: <USERNAME> # Change with actual credentials
    password: <PASSWORD> # Encrypted using hws-encrypt
    useSudo: true
    useSudoCommands: [ "MegaCli" ]

Connector Activation Criteria

The MegaCLI Managed RAID Controllers connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • Operating System is Oracle Solaris or Linux
  • The command below succeeds on the monitored host
    • Command: MegaCli -v -NoLog
    • Output contains: Exit Code: 0x00 (regex)
  • The command below succeeds on the monitored host
    • Command: MegaCli -AdpAllInfo -aALL -NoLog
    • Output contains: Exit Code: 0x00 (regex)
  • The command below succeeds on the monitored host
    • Command: MegaCli -PDList -aALL -NoLog
    • Output contains: Exit Code: 0x00 (regex)

Metrics

Type Collected Metrics Specific Attributes (Labels)
Disk Controller
  • hw.status{hw.type="disk_controller",state="present"}
  • bios_version
  • firmware_version
  • model
  • serial_number
Battery
  • hw.status{hw.type="battery",state="ok|degraded|failed"}
  • hw.status{hw.type="battery",state="present"}
  • type
Logical Disk, RAID
  • hw.logical_disk.limit
  • hw.status{hw.type="logical_disk",state="ok|degraded|failed"}
  • hw.status{hw.type="logical_disk",state="present"}
  • raid_level
Physical Disk
  • hw.physical_disk.size
  • hw.status{hw.type="physical_disk",state="ok|degraded|failed"}
  • hw.status{hw.type="physical_disk",state="present"}
  • info
  • model
No results.