Back to the list of connectors

Synology Diskstation

Description

This connector monitors the physical components of Synology DiskStation units. It relies on the SNMP Agent of Synology DiskStation Manager (DSM).

Connector ID: Synology

Target

Typical platform: Synology DiskStation

Operating system: Storage System

Prerequisites

Leverages: Synology DiskStation SNMP Agent

Technology and protocols: SNMP

This connector is not available for the local host (it is applicable to remote hosts only).

Examples

CLI

hws HOSTNAME -t storage -f Synology --snmp v2c --community public

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: storage
  selectedConnectors: [ Synology ] # Optional, to load only this connector
  snmp:
    version: v1 # Read documentation for v2 and v3
    community: public # or probably something more secure

Connector Activation Criteria

The Synology Diskstation connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.6574.1 must return a value in the same subtree

Metrics

Type Collected Metrics Specific Attributes (Labels)
Enclosure
  • hw.status{hw.type="enclosure",state="ok|degraded|failed"}
  • hw.status{hw.type="enclosure",state="present"}
  • model
  • serial_number
  • type
  • vendor
Fan
  • hw.status{hw.type="fan",state="ok|degraded|failed"}
  • hw.status{hw.type="fan",state="present"}
    Logical Disk, RAID
    • hw.status{hw.type="logical_disk",state="ok|degraded|failed"}
    • hw.status{hw.type="logical_disk",state="present"}
      Other Device
      • hw.status{hw.type="other_device",state="ok|degraded|failed"}
      • hw.status{hw.type="other_device",state="present"}
        Physical Disk
        • hw.status{hw.type="physical_disk",state="ok|degraded|failed"}
        • hw.status{hw.type="physical_disk",state="present"}
        • info
        • model
        Power Supply
        • hw.status{hw.type="power_supply",state="ok|degraded|failed"}
        • hw.status{hw.type="power_supply",state="present"}
          Temperature Sensor
          • hw.status{hw.type="temperature",state="present"}
          • hw.temperature
          • hw.temperature.limit{limit_type="high.critical"}
          • hw.temperature.limit{limit_type="high.degraded"}
            No results.