Back to the list of connectors
VMware ESXi 3.x
Description
This connector provides hardware monitoring through the VMware ESXi implementation of SMASH, through the WBEM protocol.
Connector ID: VMwareESXi
This connector is superseded by:
- CpMgServNT
- DellOpenManage
- Director52Linux
- Director5Linux
- Director61Linux
- HPInsightwbem
- ServerviewWBEM
- VMwareESX4i
This connector supersedes:
Target
Typical platform: VMware ESXi
Operating systems: Out-of-Band, Linux
Prerequisites
Leverages: WBEM
Technology and protocols: WBEM
Examples
CLI
hws HOSTNAME -t management -f VMwareESXi --wbem -u USER
hws-config.yaml
hosts:
- host:
hostname: <HOSTNAME> # Change with actual host name
type: management
selectedConnectors: [ VMwareESXi ] # Optional, to load only this connector
wbem:
protocol: https
port: 5989
username: <USERNAME> # Change with actual credentials
password: <PASSWORD> # Encrypted using hws-encrypt
Connector Activation Criteria
The VMware ESXi 3.x connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- The WBEM query below to the managed host succeeds:
- Namespace:
root/cimv2
- WQL Query:
SELECT MajorVersion FROM VMware_HypervisorSoftwareIdentity
- Result contains:
^3
(regex)
- Namespace:
Metrics
Type | Collected Metrics | Specific Attributes (Labels) |
---|---|---|
Enclosure |
|
|
Battery |
|
|
Processor |
|
|
Fan |
|
|
Memory Module |
|
|
Network Card, FC Port |
|
|
Power Supply |
|
|
Temperature Sensor |
|
|
Voltage Sensor |
|
|