Home
- TrueSight
Install the Component
This chapter explains the procedure to follow for installing, uninstalling and upgrading the Storage Analyzer TSPS Component. It also lists the prerequisites and packages required to operate Storage Analyzer within the TrueSight Presentation Server (TSPS) environment.
Install or Upgrade the TSPS Component
Before installing the TSPS Component, make sure that the following requirements are met.
Requirements
- Version 11.0 or higher of TrueSight Presentation Server (TSPS) and TrueSight Infrastructure Management (TSIM).
- PATROL Agents running Storage Analyzer must be connected to TrueSight Infrastructure Management.
- The TrueSight Infrastructure Management components must be correctly configured and running in TrueSight Presentation Server to ensure that hardware devices are fully discovered.
Once all the required steps are completed, you can proceed with the installation.
Installation and Upgrade
The installation of the TSPS Component is performed on TrueSight Presentation Server (TSPS). You need to download and to copy the installation file in a temporary location on the TSPS server itself (/tmp
as in the example below):
storage-analyzer-1.9.00-tsps.zip
Open a shell as the tsps
user on the TSPS server, and execute the below command in the /opt/bmc/TrueSightPServer/truesightpserver/bin
directory:
$ ./tssh componenttype add /tmp/storage-analyzer-1.9.00-tsps.zip
If you are updating the TSPS Component (i.e. it has already been installed on this TSPS server), you need to use the below command:
$ ./tssh componenttype update /tmp/storage-analyzer-1.9.00-tsps.zip
Normally, TSPS will be restarted:
+-------------------------------------------------------------------------------------------+
| BMC TrueSight Presentation Server - Command Line Interface 2018 version 11.3.01 |
| Copyright 2014-2018. BMC Software, Inc. as an unpublished work. All rights reserved. |
+-------------------------------------------------------------------------------------------+
Extracting the zip content
target - /opt/bmc/TrueSightPServer/truesightpserver/bin/../componenttypes/mshw-tsps_20191013_002522
Removed folder - /opt/bmc/TrueSightPServer/truesightpserver/bin/../modules/tomcat/webapps/mshw
Copying war - /opt/bmc/TrueSightPServer/truesightpserver/bin/../componenttypes/mshw-tsps/app/mshw.war
Supported plugin directory:mshw-tsps
Restarting the server
Checking system requirements
Updated component type successfully.
Nothing else needs to be configured on TSPS (there is no Component to configure in Administration > Components). The purpose of the Storage Analyzer TSPS Component is only to install on TSPS the files required by the Web UI.