VCS Group System
PATROL Class: VCS_GSYSTEM - Monitor Type: MONITOR - Monitor Category: System
No CDM Class defined.
Monitors a VCS service group system.
Service group monitoring is disabled in passive multi-node mode.
Attributes (Parameters)
| Name | PATROL Name | Units | Default Thresholds | Description |
|---|---|---|---|---|
| Auto Disabled | VCSGSystemAutoDisabled | 0 = No 1 = Yes -1 = Unknown |
ALARM |
Monitors the service group has been auto-disabled on the system by Veritas Cluster Server. Value set by VCSGroupCollector. Type: Availability - Spikes expected |
| Enabled | VCSGSystemEnabled | 0 = No 1 = Yes -1 = Unknown |
WARN |
Monitors the service group has been enabled on the system. Value set by VCSGroupCollector. Type: Availability - Spikes expected |
| Pending Probe Count | VCSGSystemPendingProbeCount | count | WARN |
Monitors the pending probes for this group system. Value set by VCSGroupCollector. Type: Statistics - Spikes expected - Baselining allowed - Default graph |
| Probed | VCSGSystemProbed | 0 = No 1 = Yes -1 = Unknown |
WARN |
Monitors the probe state of this group system. Value set by VCSGroupCollector. Type: Collection Status - Spikes expected |
| State | VCSGSystemState | 0 = ONLINE 1 = ONLINE* 2 = OFFLINE 3 = OFFLINE* 4 = STARTING 5 = STOPPING 6 = PARTIAL 7 = FAULTED -1 = UNKNOWN |
None | Displays the state of the group system. Value set by VCSGroupCollector. Type: Availability - Spikes expected |
| Status | VCSGSystemStatus | 0 = OK 1 = Suspicious 2 = Failure |
WARN ALARM |
Monitors the status of the group system. This status is determined by the status mapping configuration. Value set by VCSGroupCollector. Type: Availability - Spikes expected |
| Summary | VCSGSystemSummary | N/A | None | Summarizes the group system information as reported in the commands executed by the data collector. Value set by VCSGroupCollector. Type: Text |