Back to the list of classes

VCS Resource

PATROL Class: VCS_RESOURCE - Monitor Type: MONITOR - Monitor Category: System
No CDM Class defined.

Monitors a VCS resource.

Service group monitoring is disabled in passive multi-node mode.

Attributes (Parameters)

Name PATROL Name Units Default Thresholds Description
Failover Status VCSResourceFailoverStatus 0 = OK
1 = Suspicious
2 = Failure

 WARN
if = 1 (Suspicious)

 ALARM
if = 2 (Failure)

Monitors the failover status of the resource.

If the VCS system(s) where this resource is ONLINE differs between the current and previous collection cycles, this parameter will be set to Suspicious state. If there is no ONLINE system found for this resource, it will be set to Failure state.

Value set by VCSResourceCollector.

Type: Availability - Spikes expected

Fault System Count VCSResourceFaultSystemCount count

 WARN
if ≥ 1 count

Displays the number of systems where this resource is in FAULTED state.

Value set by VCSResourceCollector.

Type: Statistics - Spikes expected - Baselining allowed - Default graph

Offline System Count VCSResourceOfflineSystemCount count None

Displays the number of systems where this resource is in OFFLINE state.

Value set by VCSResourceCollector.

Type: Statistics - Spikes expected - Baselining allowed - Default graph

Online System Count VCSResourceOnlineSystemCount count None

Displays the number of systems where this resource is in ONLINE state.

Value set by VCSResourceCollector.

Type: Statistics - Spikes expected - Baselining allowed - Default graph

Partial System Count VCSResourcePartialSystemCount count None

Displays the number of systems where this resource is in PARTIAL state.

Value set by VCSResourceCollector.

Type: Statistics - Spikes expected - Baselining allowed - Default graph

State VCSResourceState 0 = Enabled
1 = Disabled
2 = Disabled/Critical
-1 = Unknown
None

Displays the state of the resource.

Value set by VCSResourceCollector.

Type: Availability - Spikes expected

Status VCSResourceStatus 0 = OK
1 = Suspicious
2 = Failure

 WARN
if = 1 (Suspicious)

 ALARM
if = 2 (Failure)

Monitors the frozen status of the resource. This status is determined by the resource status mapping configuration.

Value set by VCSResourceCollector.

Type: Availability - Spikes expected

Summary VCSResourceSummary N/A None

Summarizes the resource information as reported in the commands executed by the data collector.

Value set by VCSResourceCollector.

Type: Text

No results.