Back to the list of classes

VCS System

PATROL Class: VCS_SLAVE - Monitor Type: MONITOR - Monitor Category: System
No CDM Class defined.

Monitors a VCS system.

System monitoring is disabled in passive multi-node mode.

Attributes (Parameters)

Name PATROL Name Units Default Thresholds Description
CPU Available Percent VCSSystemCpuAvailablePercent %

 ALARM
if ∈ [0 %, 5 %]

 WARN
if ∈ [5 %, 10 %]

Monitors the percentage of available CPU on the system.

Value set by VCSSystemCollector.

Type: Statistics - Spikes expected - Baselining allowed - Default graph

CPU Used Percent VCSSystemCpuUsedPercent % None

Displays the percentage of CPU used by the system.

Value set by VCSSystemCollector.

Type:  KPI - Statistics - Spikes expected - Default graph

System Frozen State VCSSystemFrozenState 0 = Not Frozen
1 = TFrozen
2 = Frozen
-1 = Unknown
None

Displays the frozen state of the system.

Value set by VCSSystemCollector.

Type: Availability - Spikes expected

System Frozen Status VCSSystemFrozenStatus 0 = OK
1 = Suspicious
2 = Failure

 WARN
if = 1 (Suspicious)

 ALARM
if = 2 (Failure)

Monitors the froxen status of the system. This status is determined by the status mapping configuration.

Value set by VCSSystemCollector.

Type: Availability - Spikes expected

Load Warning Duration VCSSystemLoadWarnDuration seconds None

Indicates how long the system load has been over the warning threshold set in Veritas Cluster Server with the LoadTimeCounter system attribute.

Value set by VCSSystemCollector.

Type: Statistics - Spikes expected - Baselining allowed - Default graph

Online Group Count VCSSystemOnlineGroupCount count None

Displays the number of groups that are online or about to go online on this system.

Value set by VCSSystemCollector.

Type: Statistics - Spikes expected - Baselining allowed - Default graph

System State VCSSystemState 0 = INITING
1 = CURRENT_DISCOVER_WAIT
2 = CURRENT_PEER_WAIT
3 = STALE_DISCOVER_WAIT
4 = STALE_PEER_WAIT
5 = LOCAL_BUILD
6 = REMOTE_BUILD
7 = RUNNING
8 = ADMIN_WAIT
9 = STALE_ADMIN_WAIT
10 = LEAVING
11 = EXITING
12 = EXITING_FORCIBLY
13 = EXITED
14 = FAULTED
-1 = UNKNOWN
None

Displays the state of the system.

Value set by VCSSystemCollector.

Type: Availability - Spikes expected

System Status VCSSystemStatus 0 = OK
1 = Suspicious
2 = Failure

 WARN
if = 1 (Suspicious)

 ALARM
if = 2 (Failure)

Monitors the status of the system. This status is determined by the status mapping configuration.

Value set by VCSSystemCollector.

Type: Availability - Spikes expected

Stopped Agent Count VCSSystemStoppedAgentCount count None

Displays the number of stopped agents on the system.

Value set by VCSSystemCollector.

Type: Statistics - Spikes expected - Baselining allowed - Default graph

Summary VCSSystemSummary N/A None

Summarizes the system information as reported in the commands executed by the data collector.

Value set by VCSSystemCollector.

Type: Text

System Up Down State VCSSystemUpDownState 0 = Down
1 = Up
-1 = Unknown
None

Displays the up/down state of the system.

Value set by VCSSystemCollector.

Type: Availability - Spikes expected

System Up Down Status VCSSystemUpDownStatus 0 = OK
1 = Suspicious
2 = Failure

 WARN
if = 1 (Suspicious)

 ALARM
if = 2 (Failure)

Monitors the up/down status of the system. This status is determined by the up/down status mapping configuration.

Value set by VCSSystemCollector.

Type: Availability - Spikes expected