Attributes (Parameters)

Name PATROL Name Units Default Thresholds Description
Administrator Change NSRAdministratorChange 0 = No Change
1 = Changed
-1 = Unknown

 WARN
if = 1 (Changed)

Monitors any change in NetWorker administrator configuration between discovery cycles.

Value set by the server discovery.

Type: Availability - Spikes expected

Login Status NSRLoginStatus 0 = OK
1 = Suspicious
2 = Failure

 WARN
if = 1 (Suspicious)

 ALARM
if = 2 (Failure)

Monitors the status of the KM login details (username/password) for the operating system. If no valid username/password is found, this parameter will be set to Failure state. If there are any suspicious commands, this parameter will be set to Suspicious state.

Value set by the server discovery.

Type: Collection Status - Spikes expected - Default graph

Monitoring Mode NSRMonitoringMode 0 = Permanent Single-node Mode
1 = Temporary Single-node Mode
2 = Active Multi-node Mode
3 = Passive Multi-node Mode
-1 = Unknown
None

Monitors monitoring mode of the KM. By default, the KM runs in Permanent Single-node Mode. It can be configured to monitor in multi-node monitoring mode using the monitoring mode configuration.

Value set by the server discovery.

Type: Collection Status - Spikes expected - Default graph

Monitor RAP NSRMonitorRAP 0 = Enabled
1 = Disabled
-1 = Unknown
None

Collects the status of the NetWorker RAP (Resource Allocation Protocol) monitor configuration.

Value set by the server discovery.

Type: Availability - Spikes expected

Node Status NSRNodeStatus 0 = OK
1 = Suspicious
2 = Failure

 WARN
if = 1 (Suspicious)

 ALARM
if = 2 (Failure)

Monitors error messages for the EMC NetWorker application on this managed system. If the node is unreachable or if any of the EMC NetWorker application daemons is not running, this parameter will be set to Failure state. The list of critical EMC NetWorker daemons can be customized using the node status configuration menu. If there are any node status related errors from the server, this parameter will be set to Suspicious state.

Value set by the server discovery.

Type: Collection Status - Spikes expected - Default graph

Server Summary NSRServerSummary N/A None

Summarizes the server information as reported in commands executed by the discovery.

Value set by the server discovery.

Type: Text