Back to the list of connectors
Adaptec - StorMan - RAID
Description
This connector provides information about physical disks and volumes for Adaptec SAS RAID controllers through the arcconf utility.
Connector file name: MS_HW_AdptStorManUnix.hdf
Target
Typical platform: Any system with Adaptec
Operating systems: Oracle Solaris, Linux
Prerequisites
Leverages: arcconf
Technology and protocols: System Commands
This connector requires advanced privileges on the managed host for the command below:
/[opt|usr]/StorMan/arcconf
This connector therefore needs to run as root or you need to configure a privilege-escalation mechanism like sudo
on the managed host to allow the monitoring account to run the command listed above.
Sample of /etc/sudoers to allow the above command to be run as root by the patrol account:
patrol ALL=(root) NOPASSWD: /[opt|usr]/StorMan/arcconf
Connector Activation Criteria
The Adaptec - StorMan - RAID connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- Operating System is Oracle Solaris or Linux
- The command below succeeds on the monitored host
- Command:
/bin/sh %EmbeddedFile(1)%
- Output contains:
Hard drive
(regex)
- Command:
Monitors
Object Type | Collected Parameters | Discovered Properties |
---|---|---|
Disk Controller (MS_HW_DISKCONTROLLER ) |
|
|
Battery (MS_HW_BATTERY ) |
|
|
Logical Disk, RAID (MS_HW_LOGICALDISK ) |
|
|
Physical Disk (MS_HW_PHYSICALDISK ) |
|
|