Blade Chassis
Platform | Technology/Protocols | Hardware Connector | Instrumentation Prerequisites |
---|---|---|---|
Cisco UCS | HTTP/REST | Cisco UCS Manager (REST) | Cisco UCS Manager (REST XML API) |
Cisco UCS | SNMP | Cisco UCS S-Series CIMC (SNMP) | Cisco S-Series CIMC |
Dell M1000E | System Commands | Dell CMC (Dell Chassis Management Controller) | Dell Chassis Management Controller (CMC) |
Dell MX7000 | HTTP/REST | Dell MX Chassis and Blades (REST) | N/A |
Dell MX7000 Chassis | System Commands | Dell MX7000 Chassis | Dell MX7000 Management Module |
Dell PowerEdge | System Commands | Dell DRAC/MC (Dell Remote Access Controller/Modular Chassis) | Dell Remote Access Controller/Modular Chassis (DRAC/MC) |
Fujitsu-Siemens BX Blade | SNMP | Fujitsu-Siemens Management Blade (FSC BX Blade Servers) | Fujitsu-Siemens Management Blade |
Hitachi BladeSymphony | SNMP | Hitachi BladeSymphony Chassis | Hitachi BladeSymphony Chassis Management Module |
Hitachi Compute Blade | SNMP | Hitachi Compute Blade Chassis | Hitachi Compute Blade Chassis Management Module |
HP BladeSystem | SNMP | HP BladeSystem (SNMP) | HP iLO / HP Insight Management Agents |
HP BladeSystem | System Commands | HP BladeSystem (SSH) | HP BladeSystem Onboard Administrator |
HP Synergy REST | HTTP/REST | HP Synergy - REST | N/A |
IBM BladeCenter | SNMP | IBM BladeCenter Management Module | IBM BladeCenter Management Module |
Intel Modular | SNMP | Intel Modular Server | Intel Server Manager 8 SNMP Agents |
Any system with IPMI | IPMI | IPMI | IPMI |
HP OpenVMS
Platform | Technology/Protocols | Hardware Connector | Instrumentation Prerequisites |
---|---|---|---|
HP ProLiant | SNMP | HP Insight Management Agent - SCSI Storage HP Insight Management Agent - iLO HP Insight Management Agent - Network HP Insight Management Agent (v8.20 or lower) - Memory HP Insight Management Agent - IDE Storage HP Insight Management Agent - Fiber Array HP Insight Management Agent - HBA HP Insight Management Agent (v8.25 or higher) - Memory HP Insight Management Agent - Server HP Insight Management Agent - Drive Array HP Insight Management Agent - Server (Alpha) |
HP Insight Management Agents |
Any system with Emulex Any system with QLogic |
WBEM | SMI-S Compliant HBAs | SMI-S Agent provided by the HBA vendor |
Any system with SNMP | SNMP | MIB-2 Standard SNMP Agent - Network Interfaces | MIB-2 Standard SNMP Agent |
HP Tru64
Platform | Technology/Protocols | Hardware Connector | Instrumentation Prerequisites |
---|---|---|---|
HP ProLiant | SNMP | HP Insight Management Agent - SCSI Storage HP Insight Management Agent - iLO HP Insight Management Agent - Network HP Insight Management Agent (v8.20 or lower) - Memory HP Insight Management Agent - IDE Storage HP Insight Management Agent - Fiber Array HP Insight Management Agent - HBA HP Insight Management Agent (v8.25 or higher) - Memory HP Insight Management Agent - Server HP Insight Management Agent - Drive Array HP Insight Management Agent - Server (Alpha) |
HP Insight Management Agents |
Any system with Emulex Any system with QLogic |
WBEM | SMI-S Compliant HBAs | SMI-S Agent provided by the HBA vendor |
Any system with SNMP | SNMP | MIB-2 Standard SNMP Agent - Network Interfaces | MIB-2 Standard SNMP Agent |
HP-UX
Platform | Technology/Protocols | Hardware Connector | Instrumentation Prerequisites |
---|---|---|---|
HP 9000 HP Integrity HP SuperDome |
System Commands | HP-UX - sasmgr Disk Controllers HP-UX - HBA HP-UX - Network HP-UX - Common HP-UX - Smart Array RAID HP-UX - Disks HP-UX (STM) |
HP-UX system commands (sasmgr, ioscan etc.) HP UX system commands (ioscan, fcmsutil) HP-UX system commands (lanscan, etc.) HP-UX system commands (ioscan, etc.) HP-UX Smart Array Configuration Utility HP-UX system commands (pvdisplay, ioscan, etc.) HP-UX Support Tools Manager (STM) |
HP 9000 HP Integrity HP SuperDome |
WBEM | HP-UX (WBEM) HP-UX - Network (WBEM) |
HP-UX WBEM Provider |
Any system with EMC PowerPath | System Commands | EMC PowerPath (powermt) | EMC powermt utility |
Any system with Emulex Any system with QLogic |
WBEM | SMI-S Compliant HBAs | SMI-S Agent provided by the HBA vendor |
Any system with SNMP | SNMP | MIB-2 Standard SNMP Agent - Network Interfaces | MIB-2 Standard SNMP Agent |
IBM AIX
Platform | Technology/Protocols | Hardware Connector | Instrumentation Prerequisites |
---|---|---|---|
IBM POWER | System Commands | IBM AIX - Common IBM AIX - HBA IBM AIX - usysfault IBM AIX - LUN IBM AIX - CHRP Environment IBM VIO Server IBM AIX - SCSI disks IBM AIX - Environment (uesensor) IBM AIX - sissasraidmgr Disk Controllers |
IBM AIX system commands (lsdev, entstat, etc.) IBM AIX system commands (lsdev, lsattr, fcstat, etc.) IBM AIX usysfault command IBM AIX lspath system command IBM AIX system commands (machstat) IBM AIX system commands through the IOS interface (lsdev, entstat, etc.) IBM AIX system commands (lsdev, pvdisplay, etc.) IBM AIX system commands (uesensor) sissasraidmgr managed RAID card |
Any system with EMC PowerPath | System Commands | EMC PowerPath (powermt) | EMC powermt utility |
Any system with Emulex Any system with QLogic |
WBEM | SMI-S Compliant HBAs | SMI-S Agent provided by the HBA vendor |
Linux
Platform | Technology/Protocols | Hardware Connector | Instrumentation Prerequisites |
---|---|---|---|
Dell PowerEdge | SNMP | Dell OpenManage Array Manager Dell OpenManage Storage Manager Dell OpenManage Server Administrator |
Dell OpenManage Server Administrator |
Fujitsu-Siemens PRIMERGY | SNMP | Adaptec IOManager LsiLogic MegaRAID PowerConsole Adaptec Storage Manager (DPT) Fujitsu-Siemens Serverview Fujitsu-Siemens ServerView RAID Agent LsiLogic MegaRAID SAS LSI 1030-based GAM Server (Alternate MIB) LSI 1030-based GAM Server Promise FastTrack Fujitsu-Siemens Serverview - Agent (v8 or higher) Adaptec Storage Manager Web Edition (AAC) LSI/Mylex GAM Server LsiLogic MegaRAID SAS (Newer Controllers) |
Adaptec IOManager LSI MegaRAID PowerConsole Adaptec Storage Manager Fujitsu-Siemens Serveview Agent Fujitsu-Siemens Serverview RAID Agent LSI MegaRAID SAS SNMP Agent LSI GAM Server Promise FastTrack SNMP Agent Adaptec Storage Manager Web Edition Mylex GAM Server |
Fujitsu-Siemens PRIMERGY | WBEM | Fujitsu-Siemens Serverview (WBEM) | Fujitsu-Siemens Serverview WBEM Agent |
HP BladeSystem | SNMP | HP BladeSystem (SNMP) | HP iLO / HP Insight Management Agents |
HP ProLiant | SNMP | HP Insight Management Agent - SCSI Storage HP Insight Management Agent - iLO HP Insight Management Agent - Network HP Insight Management Agent (v8.20 or lower) - Memory HP Insight Management Agent - IDE Storage HP Insight Management Agent - Fiber Array HP Insight Management Agent - HBA HP Insight Management Agent (v8.25 or higher) - Memory HP Insight Management Agent - Server HP Insight Management Agent - Drive Array |
HP Insight Management Agents |
HP ProLiant | WBEM | HP Insight Management Agent - Server (WBEM) | HP Insight Management Agents (WBEM) |
IBM POWER | System Commands | IBM Hardware Management Console (HMC) Version 7 or earlier IBM Hardware Management Console (HMC) Version 8 or later |
IBM Hardware Management Console (HMC) |
IBM xSeries | WBEM | IBM Director Agent 5.10.x - Linux IBM Director Agent 5.20.x - Linux IBM Director Agent 6 - Linux |
IBM Director Agent 5.10.x IBM Director Agent 5.20.x IBM Director Agent 6.1.x |
KVM QEMU Xen Hypervisors |
System Commands | KVM, QEMU, Xen and Hypervisors (virsh) | libvirt API |
NEC Express5800 | SNMP | NEC ESMPRO Agent | NEC ESMPRO Agent |
Oracle/Sun | SNMP | Oracle Hardware Management Agent | Oracle Hardware Management Pack |
Proxmox Hypervisors | HTTP/REST | Promox Virtual Environment (REST) | Proxmox VE REST API version V6.4-14 or higher |
Any system | System Commands | Linux - Network (ip) lm_sensors Linux - Network (ifconfig) |
Linux system commands (ip) lm_sensors Linux system commands (ifconfig) |
Any system with Adaptec | System Commands | Adaptec - StorMan - RAID | arcconf |
Any system with EMC PowerPath | System Commands | EMC PowerPath (powermt) | EMC powermt utility |
Any system with Emulex | System Commands | Emulex HBAs (hbacmd) | Emulex's hbacmd utility |
Any system with Emulex Any system with QLogic |
WBEM | SMI-S Compliant HBAs | SMI-S Agent provided by the HBA vendor |
Any system with Fusion IO | System Commands | Fusion ioDrive (fio-status) | fio-status CLI utility |
Any system with Intel Base Board 5 | SNMP | Intel Base Board 5 Motherboards | Intel Server Manager 8 SNMP Agents |
Any system with IPMI | IPMI | IPMI | IPMI |
Any system with LSI lsiutil | System Commands | LSI Logic - LsiUtil - RAID | lsiutil |
Any system with LSI MegaCli | System Commands | MegaCLI Managed RAID Controllers | MegaCli (LSI) managed RAID card |
Any system with LSI sas2ircu | System Commands | LSI sas2ircu Managed Raid Controllers | Sas2Ircu (LSI) managed RAID card |
Any system with multipath | System Commands | Linux - Multipath | Linux multipath utility |
Any system with Nvidia GPUs | System Commands | Nvidia-Smi | NVIDIA drivers with NVIDIA-SMI support. |
Any system with QLogic | System Commands | QLogic HBAs (scli) | QLogic's SCLI utility |
Any system with RAID Controller | WBEM | SMI-S Compliant RAID Controller - Linux | SMI-S Compliant WBEM Provider |
Any system with SmartMon | System Commands | SmartMon Tools | SmartMon Tools |
Any system with SNMP | SNMP | MIB-2 Standard SNMP Agent - Network Interfaces - Linux | MIB-2 Standard SNMP Agent |
Microsoft Windows
Platform | Technology/Protocols | Hardware Connector | Instrumentation Prerequisites |
---|---|---|---|
Dell PowerEdge | SNMP | Dell OpenManage Array Manager Dell OpenManage Storage Manager Dell OpenManage Server Administrator |
Dell OpenManage Server Administrator |
Fujitsu-Siemens PRIMERGY | SNMP | Adaptec IOManager LsiLogic MegaRAID PowerConsole Adaptec Storage Manager (DPT) Fujitsu-Siemens Serverview Fujitsu-Siemens ServerView RAID Agent LsiLogic MegaRAID SAS LSI 1030-based GAM Server (Alternate MIB) LSI 1030-based GAM Server Promise FastTrack Fujitsu-Siemens Serverview - Agent (v8 or higher) Adaptec Storage Manager Web Edition (AAC) LSI/Mylex GAM Server LsiLogic MegaRAID SAS (Newer Controllers) |
Adaptec IOManager LSI MegaRAID PowerConsole Adaptec Storage Manager Fujitsu-Siemens Serveview Agent Fujitsu-Siemens Serverview RAID Agent LSI MegaRAID SAS SNMP Agent LSI GAM Server Promise FastTrack SNMP Agent Adaptec Storage Manager Web Edition Mylex GAM Server |
Fujitsu-Siemens PRIMERGY | WMI | Fujitsu-Siemens Serverview (WMI) | Fujitsu-Siemens Serverview WBEM Agent |
HP BladeSystem | SNMP | HP BladeSystem (SNMP) | HP iLO / HP Insight Management Agents |
HP ProLiant | SNMP | HP Insight Management Agent - SCSI Storage HP Insight Management Agent - iLO HP Insight Management Agent - Network HP Insight Management Agent (v8.20 or lower) - Memory HP Insight Management Agent - IDE Storage HP Insight Management Agent - Fiber Array HP Insight Management Agent - HBA HP Insight Management Agent (v8.25 or higher) - Memory HP Insight Management Agent - Server HP Insight Management Agent - Drive Array |
HP Insight Management Agents |
HP ProLiant | WMI | HP Insight Management Agent - Server (WMI) | HP Insight Management Agents (WMI) |
Hyper-V Servers | System Commands | Hyper-V | PowerShell |
IBM xSeries | WMI | SMI-S Compliant RAID Controller - Windows IBM Director Agent 6 - Windows IBM Director Agent 5.10.x - Windows IBM Director Agent 5.20.x - Windows |
IBM Director Agent 5.20.x / 6.10.x IBM Director Agent 6 IBM Director Agent 5.10.x IBM Director Agent 5.20.x |
NEC Express5800 | SNMP | NEC ESMPRO Agent | NEC ESMPRO Agent |
Oracle/Sun | SNMP | Oracle Hardware Management Agent | Oracle Hardware Management Pack |
Any system | System Commands | Windows - DiskPart | The DISKPART.EXE command-line utility |
Any system | WMI | Windows Storage Spaces (WMI) WMI - LUN WMI - HBA WMI - Network WMI - Disks WMI - Battery |
Windows Storage Spaces WMI |
Any system with EMC PowerPath | System Commands | EMC PowerPath (powermt) | EMC powermt utility |
Any system with Emulex Any system with QLogic |
WBEM | SMI-S Compliant HBAs | SMI-S Agent provided by the HBA vendor |
Any system with Fusion IO | System Commands | Fusion ioDrive (fio-status) | fio-status CLI utility |
Any system with Intel Base Board 5 | SNMP | Intel Base Board 5 Motherboards | Intel Server Manager 8 SNMP Agents |
Any system with IPMI | IPMI | IPMI | IPMI |
Any system with LSI lsiutil | System Commands | LSI Logic - LsiUtil - RAID (Windows) | lsiutil |
Any system with LSI MegaCli | System Commands | LSI MegaCli | Windows system commands (MegaCli / CmdTool2) |
Any system with Nvidia GPUs | System Commands | Nvidia-Smi | NVIDIA drivers with NVIDIA-SMI support. |
Any system with SNMP | SNMP | MIB-2 Standard SNMP Agent - Network Interfaces - Windows | MIB-2 Standard SNMP Agent |
Any Windows system | WMI | Libre Hardware Monitor | Libre Hardware Monitor |
Network Device
Platform | Technology/Protocols | Hardware Connector | Instrumentation Prerequisites |
---|---|---|---|
Aruba | SNMP | Aruba (SNMP) | SNMP Agent |
Cisco | SNMP | Cisco Ethernet Switch Cisco Entity Sensor (SNMP) |
Cisco SNMP Agent (ciscoMgmt) |
DELL PowerSwitch S4000 Series | SNMP | DELL PowerSwitch S-Series | Switch's SNMP agent |
Extreme | SNMP | Extreme Networks (SNMP) | SNMP Agent |
F5 BigIP | SNMP | F5 BigIP Switch | F5 SNMP Agent (bigipSystem) |
HP Procurve | SNMP | HP Procurve (SNMP) | HP Procurve (HP-ICF-CHASSIS) |
Juniper Network Switch | SNMP | Juniper Switch | Juniper SNMP Agent (JUNIPER-MIB) |
MIB-2 and Entity-Sensor-MIB Supported Switch | SNMP | Ethernet Switch with Sensors (SNMP) | MIB-2, Entity-Sensor-MIB, SNMP |
MIB-2 Supported Switch | SNMP | Generic Ethernet Switch | MIB-2 SNMP |
Netscreen | SNMP | Juniper Netscreen (SNMP) | Juniper SNMP Agent (NETSCREEN-CHASSIS-MIB) |
Oracle/Sun Infiniband DCS | SNMP | Oracle/Sun InfiniBand DCS Switch (Ports) | Oracle/Sun ILOM SNMP Agent |
Oracle/Sun Xsigo | SNMP | Oracle/Sun Xsigo Switch | Sun Xsigo SNMP Agent |
Any system with SNMP | SNMP | MIB-2 Standard SNMP Agent - Network Interfaces | MIB-2 Standard SNMP Agent |
Oracle Solaris
Platform | Technology/Protocols | Hardware Connector | Instrumentation Prerequisites |
---|---|---|---|
HP BladeSystem | SNMP | HP BladeSystem (SNMP) | HP iLO / HP Insight Management Agents |
HP ProLiant | SNMP | HP Insight Management Agent - SCSI Storage HP Insight Management Agent - iLO HP Insight Management Agent - Network HP Insight Management Agent (v8.20 or lower) - Memory HP Insight Management Agent - IDE Storage HP Insight Management Agent - Fiber Array HP Insight Management Agent - HBA HP Insight Management Agent (v8.25 or higher) - Memory HP Insight Management Agent - Server HP Insight Management Agent - Drive Array |
HP Insight Management Agents |
Oracle/Sun | SNMP | Oracle Hardware Management Agent | Oracle Hardware Management Pack |
Oracle/Sun | System Commands | Oracle/Sun Solaris - Network Oracle/Sun Solaris - Fault Manager - Memory and CPU Oracle/Sun Solaris - Environment (ALOM-CMT snapshot) Oracle/Sun Solaris - Tape Drives Oracle/Sun Solaris - Memory Modules (cediag) Oracle/Sun Solaris - Sun Disks Oracle/Sun Solaris - Processors (psrinfo) Oracle/Sun Solaris - Multi-core Processors (psrinfo) Oracle/Sun Solaris - Environment (prtpicl) Oracle/Sun Solaris - RAID Disks (raidctl) Oracle/Sun Solaris - Non-Sun Disks Oracle/Sun Solaris - Environment (prtdiag, lom) |
Sun Solaris system commands (kstat, ndd, ifconfig, dladm, etc.) Sun Solaris system commands (fmadm) Sun Explorer and the ALOM-CMT card Sun Solaris system commands (iostat, dd) Sun Solaris system commands (cediag, cestat) Sun Solaris system commands (psrinfo, etc.) Sun Solaris system commands (prtpicl, etc.) Sun Solaris system commands (raidctl) Sun Solaris system commands (prtdiag, lom, etc.) |
Oracle/Sun Enterprise Mx000 | System Commands | Oracle/Sun Enterprise Mx000 (XSCF) | Sun XSCF utilities installed on the System Controller |
Oracle/Sun Fire F15K | System Commands | Oracle/Sun Fire F12K/F15K/F20K/F25K (SMS) | Sun SMS utilities installed on the System Controller (SC on F15K, etc.) |
Any system with Adaptec | System Commands | Adaptec - StorMan - RAID | arcconf |
Any system with EMC PowerPath | System Commands | EMC PowerPath (powermt) | EMC powermt utility |
Any system with Emulex | System Commands | Emulex HBAs (hbacmd) | Emulex's hbacmd utility |
Any system with Emulex Any system with QLogic |
WBEM | SMI-S Compliant HBAs | SMI-S Agent provided by the HBA vendor |
Any system with Fusion IO | System Commands | Fusion ioDrive (fio-status) | fio-status CLI utility |
Any system with IPMI | IPMI | IPMI | IPMI |
Any system with LSI lsiutil | System Commands | LSI Logic - LsiUtil - RAID | lsiutil |
Any system with LSI MegaCli | System Commands | MegaCLI Managed RAID Controllers | MegaCli (LSI) managed RAID card |
Any system with mpathadm | System Commands | Oracle/Sun Solaris - mpathadm | Solaris Mpathadm utility |
Any system with QLogic | System Commands | QLogic HBAs (scli) | QLogic's SCLI utility |
Any system with SNMP | SNMP | MIB-2 Standard SNMP Agent - Network Interfaces - Solaris | MIB-2 Standard SNMP Agent |
Out-of-Band
Platform | Technology/Protocols | Hardware Connector | Instrumentation Prerequisites |
---|---|---|---|
APC PDU | SNMP | APC PDU (SNMP) | PDU SNMP Enabled |
APC UPS | SNMP | APC UPS | UPS SNMP Enabled |
Cisco B-Series Servers | SNMP | Cisco UCS B-Series (SNMP) | Cisco UCS Manager SNMP Agent |
Cisco UCS | SNMP | Cisco UCS C-Series CIMC (SNMP) | Cisco CIMC |
Dell PowerEdge | SNMP | Dell iDRAC - Storage Dell iDRAC - Server |
Dell iDRAC Management Card (iDRAC7 or Later) |
Eaton PDU | SNMP | Eaton PDU (SNMP) | PDU SNMP Enabled |
Fujitsu-Siemens PRIMERGY | WBEM | Fujitsu-Siemens Serverview (WBEM) | Fujitsu-Siemens Serverview WBEM Agent |
HP iLO Gen 10 REST | HTTP/REST | HP iLO Gen 10 (REST) | N/A |
HP iLO Gen 9 REST | HTTP/REST | HP iLO Gen 9 (REST) | N/A |
HP ProLiant | SNMP | HP Insight Management Agent - SCSI Storage HP Insight Management Agent - iLO HP Insight Management Agent (v8.20 or lower) - Memory HP Integrated Lights-Out Management Card - Network HP Insight Management Agent - IDE Storage HP Insight Management Agent - Fiber Array HP Insight Management Agent - HBA HP Insight Management Agent (v8.25 or higher) - Memory HP Insight Management Agent - Server HP Insight Management Agent - Drive Array |
HP Insight Management Agents HP Integrated Lights-Out Management Card |
HP ProLiant | WBEM | HP Insight Management Agent - Server (WBEM) | HP Insight Management Agents (WBEM) |
Huawei | SNMP | Huawei Servers - Management Card | Huawei iMana or iBMC Management Card |
IBM DataPower | SNMP | IBM DataPower (SNMP) | IBM DataPower SNMP Agent |
iDRAC9 REST | HTTP/REST | Dell iDRAC9 (REST) | N/A |
Lenovo | SNMP | Lenovo IMM (SNMP) Lenovo IMM Event Monitoring (SNMP) |
Lenovo IMM's SNMP Service |
Lenovo Server | SNMP | Lenovo ThinkSystem Rack Mount Server | Lenovo ThinkSystem SNMP Agent |
Oracle/Sun | SNMP | Oracle/Sun ILOM (SNMP) | Sun/Oracle ILOM SNMP Agent |
Oracle/Sun | System Commands | Oracle/Sun ILOM (SSH) | Sun/Oracle ILOM |
Oracle/Sun Blade | SNMP | Oracle/Sun Blade Chassis | Sun Blade Chassis CMM SNMP Agent |
Oracle/Sun Enterprise Mx000 | System Commands | Oracle/Sun Enterprise Mx000 (XSCF) | Sun XSCF utilities installed on the System Controller |
Oracle/Sun Fire F15K | System Commands | Oracle/Sun Fire F12K/F15K/F20K/F25K (SMS) | Sun SMS utilities installed on the System Controller (SC on F15K, etc.) |
Proxmox Hypervisors | HTTP/REST | Promox Virtual Environment (REST) | Proxmox VE REST API version V6.4-14 or higher |
Quanta Server | SNMP | Quanta Rack Mount Server Unit | Quanta System Manager SNMP Agent |
Raritan PDU | SNMP | Raritan PDU (SNMP) | PDU SNMP Enabled |
SuperMicro | HTTP/REST | SuperMicro (REST) | SuperMicro Baseboard Management Controller REST API |
Any system with Emulex Any system with QLogic |
WBEM | SMI-S Compliant HBAs | SMI-S Agent provided by the HBA vendor |
Any system with RAID Controller | WBEM | SMI-S Compliant RAID Controller - Linux | SMI-S Compliant WBEM Provider |
Any system with SNMP | SNMP | MIB-2 Standard SNMP Agent - Network Interfaces | MIB-2 Standard SNMP Agent |
Any UPS which supports UPS-MIB (RFC1628) | SNMP | Generic UPS | N/A |
Storage System
Platform | Technology/Protocols | Hardware Connector | Instrumentation Prerequisites |
---|---|---|---|
Brocade SAN | SNMP | Brocade SAN Switch | Brocade SNMP Agent (fcSwitch) |
Brocade SAN | WBEM | Brocade SAN Switch SMI Agent | Brocade SMI Agent |
Cisco SAN | System Commands | Cisco MDS9000 Series (SSH) | Commands on the Cisco Bay Controller |
Data Domain | SNMP | Data Domain Storage Appliance (SNMP) | Data Domain SNMP Agent |
DataDirect Networks (DDN) | SNMP | DataDirect Networks (DDN) Disk Array (SNMP) DataDirect Networks (DDN) Storage Appliance (SNMP) |
DDN SNMP Agent |
Dell Compellent | HTTP/REST | Dell Compellent Storage Manager - Unisphere For Storage Center Dell Compellent Storage Center |
Dell Compellent Storage Manager REST API Dell Compellent Controller REST API |
Dell EqualLogic | SNMP | Dell EqualLogic PS Series | Dell EqualLogic SNMP Agent (EQLGROUP-MIB) |
DELL MD3000 | System Commands | DELL MD3000 (LSI) Disk Arrays (smcli) | The SMcli utility, which is part of Dell PowerVault Modular Disk Storage Manager. The version must be compatible with the system being monitored. Multiple versions of SMcli on the same system is not supported. |
Dell TL2000/4000 Tape Library | SNMP | Dell PowerVault TL2000/4000 Tape Libraries | Dell SNMP Agent (DELL-SHADOW-MIB) |
EMC Celerra EMC VNX Unified |
System Commands | EMC Celerra/VNX Unified System (SSH) | EMC naviseccli and nas_inventory utilities |
EMC CLARiiON EMC VNX |
System Commands | EMC Navisphere CLI (Local User) EMC Navisphere CLI (Global User) EMC Navisphere CLI (LDAP User) |
EMC naviseccli utility |
EMC Isilon | HTTP/REST | EMC Isilon Cluster (REST) | N/A |
EMC Isilon | SNMP | EMC Isilon - Node (SNMP) | EMC Isilon SNMP Agent |
EMC Isilon | System Commands | EMC Isilon (SSH) EMC Isilon 8 (SSH) |
EMC Isilon SSH interface |
EMC Symmetrix EMC VMAX EMC CLARiiON EMC VNX |
WBEM | EMC SMI-S Agent (ECOM) | EMC SMI-S Agent (ECOM) |
EMC Unity | WBEM | EMC Unity SMI-S Agent | EMC Unity SMI-S Agent |
EMC VNXe | System Commands | EMC uemcli (VNXe) | uemcli |
EMC VPLEX | HTTP/REST | EMC VPLEX Version 6 EMC VPLEX Version 5 |
EMC VPLEX REST API Version 6 and Higher EMC VPLEX REST API Version 5 and lower |
Fujitsu Eternus | WBEM | Fujitsu Eternus DX Disk Arrays | Fujitsu Eternus SMI-S Server |
Hitachi AMS Hitachi HUS |
System Commands | Hitachi HDS AMS/HUS (SNM2 CLI on Linux) Hitachi HDS AMS/HUS (SNM2 CLI on Windows) |
Hitachi SNM2 CLI |
Hitachi AMS Hitachi HUS Hitachi USP Hitachi VSP |
WBEM | Hitachi Storage Command Suite SMI-S Agent | Hitachi Storage Command Suite SMI-S Agent |
Hitachi HNAS | SNMP | Hitachi HNAS (SNMP) | Hitachi HNAS SNMP Agent |
Hitachi USP Hitachi VSP |
SNMP | Hitachi HDS USP/VSP (SNMP) | Hitachi SNMP Agent |
Hitachi VSP F-Series and VSP G-Series Storage Systems | HTTP/REST | Hitachi G-Series (REST) Hitachi Configuration Manager (REST) |
Hitachi SVP REST Hitachi Configuration Manager |
Hitachi VSP G Series Hitachi HUS-VM |
WBEM | Hitachi SVP SMI-S Agent | Hitachi VSP SMI-S Agent |
HP Qumulo storage systems | System Commands | HP Qumulo with Python HP Qumulo |
QQ CLI |
HP StorageWorks EVA | System Commands | HP StorageWorks EVA (SSSU) - Linux HP StorageWorks EVA (SSSU) - Windows |
HP StorageWorks Command View EVA SSSU |
HP StorageWorks P2000 G3 | WBEM | HP P2000 G3 or Later (WBEM) | HP P2000 Management Card |
HPE Primera / HP 3PAR | WBEM | HPE Primera / HP 3PAR Disk Array | HPE Primera / HP 3PAR Embedded SMI-S Provider |
Huawei OceanStor | HTTP/REST | Huawei OceanStor (REST) | Huawei DeviceManager REST API |
Huawei OceanStor | SNMP | Huawei Storage System (OceanStor) | Huawei Storage System SNMP Agent |
IBM 3584 IBM TS3000 Tape Libraries |
SNMP | SNIA Compliant Tape Libraries (SNMP) | SNIA Compliant SNMP Agent (SNIA-SML-MIB) |
IBM DS3000 IBM DS4000 IBM DS5000 |
System Commands | IBM DS (LSI) Disk Arrays (smcli) | The SMcli utility, which is part of IBM DS Storage Manager. The version must be compatible with the system being monitored. Multiple versions of SMcli on the same system is not supported. |
IBM DS6000 DS8000 |
WBEM | IBM DS6000/8000 Disk Arrays | IBM SMI-S Agent (IBM System Storage DS6000/DS8000 Storage Manager) |
IBM FlashSystem | SNMP | IBM FlashSystem 700/800 IBM FlashSystem 900 |
IBM FlashSystem 700/800 SNMP Agent IBM FlashSystem 900 SNMP Agent |
IBM Storwize | System Commands | IBM Storwize Disk Arrays (SSH) | IBM Storwize SSH console |
IBM TS3100 Tape Library | SNMP | IBM TS3100 Tape Libraries | IBM SNMP Agent SNMP Agent (IBM-3100-MIB) |
IBM TS3200 Tape Library | SNMP | IBM TS3200 Tape Libraries | IBM SNMP Agent SNMP Agent (IBM-3200-MIB) |
IBM XiV Storage System | System Commands | IBM XIV (xcli) | xcli command line utility |
MacroSan | SNMP | MacroSan Storage System (SNMP) | MacroSan SNMP Agent |
McData SAN | SNMP | McData Fibre Switch | McData SNMP Agent (EF-6000-MIB) |
NetApp | HTTP/REST | NetApp Filer (REST) NetApp 7-Mode Filer (REST) |
NetApp REST API |
NetApp | SNMP | NetApp Filer (SNMP) | NetApp SNMP Agent |
NetApp E-Series | HTTP/REST | NetApp E-Series | N/A |
NetApp SolidFire | HTTP/REST | NetApp SolidFire (REST) | SolidFire API |
Nimble | HTTP/REST | Nimble | Nimble REST API |
Oracle ZFS Storage Appliance | System Commands | Oracle/Sun ZFS Storage Appliance | Oracle ZFS Command Line (SSH) |
Oracle/Sun | SNMP | Oracle/Sun ILOM (SNMP) | Sun/Oracle ILOM SNMP Agent |
Oracle/Sun Infiniband DCS | SNMP | Oracle/Sun InfiniBand DCS Switch (Ports) | Oracle/Sun ILOM SNMP Agent |
Oracle/Sun Xsigo | SNMP | Oracle/Sun Xsigo Switch | Sun Xsigo SNMP Agent |
PowerStore REST | HTTP/REST | Dell EMC PowerStore (REST) | N/A |
PowerVault REST | HTTP/REST | Dell EMC PowerVault (REST) | N/A |
Pure Storage | HTTP/REST | Pure Storage FA Series (REST Token Authentication) Pure Storage FA Series (REST) |
Pure Storage REST API |
Pure Storage | System Commands | Pure Storage FA Series (SSH) | Pure Storage Management Card |
Quantum (ADIC) Scalar Tape Library | SNMP | Quantum (ADIC) based Tape Libraries | Quantum SNMP Agent (ADIC-TAPE-LIBRARY-MIB) |
Quantum DXi | System Commands | Quantum DXi (SSH) | Commands on the Quantum DXi controller |
Quantum i40/i80 (ADIC) Scalar Tape Library | SNMP | Quantum i40/i80 (ADIC) based Tape Libraries | Quantum SNMP Agent (ADIC-TAPE-LIBRARY-MIB) |
Quantum Scalar i2000 Quantum Scalar i6000 |
SNMP | Quantum (ADIC) Enterprise Level Tape Libraries | Quantum SNMP Agent (ADIC-MANAGEMENT-MIB) |
StorageTek LSeries | SNMP | StorageTek LSeries Tape Library | StorageTek LSeries SNMP Agent |
StorageTek StreamLine | SNMP | StorageTek StreamLine Tape Library | StorageTek StreamLine SNMP Agent |
Synology DiskStation | SNMP | Synology Diskstation | Synology DiskStation SNMP Agent |
X1 | HTTP/REST | Dell XtremIO - REST | N/A |
Any SAN switch | SNMP | Fibre Alliance SNMP Agent (Switches) | Fibre Alliance SNMP Agent (FCMGMT-MIB) |
Any SMI-S compliant disk array | WBEM | SMI-S Compliant Disk Arrays | SMI-S Agent provided by the array vendor |
Any SMI-S compliant SAN switch | WBEM | SMI-S Compliant SAN Switches | SMI-S Agent provided by the switch vendor |
Any SMI-S compliant storage library | WBEM | SMI-S Compliant Storage Libraries | SMI-S Agent provided by the library vendor |
Any system with SNMP | SNMP | MIB-2 Standard SNMP Agent - Network Interfaces | MIB-2 Standard SNMP Agent |
VMware ESX
Platform | Technology/Protocols | Hardware Connector | Instrumentation Prerequisites |
---|---|---|---|
VMware ESXi | SNMP | VMware ESXi - Virtual Machines (SNMP) | SNMP |
VMWare ESXi | System Commands | VMware ESXi 5 LUN (SSH) VMware ESXi 5 LUN (esxcli) |
ESX SSH interface ESX excli utility (installed locally on the agent host) |
VMware ESXi | WBEM | VMware ESXi 3.x VMware ESXi 4.x VMware ESXi - Disks (VMware) VMware ESXi - Disks (IPMI) |
WBEM |
Any system with QLogic | WBEM | QLogic HBAs - VMware ESX | QLogic CIM Agent for VMware ESX |