Back to the list of connectors
IBM Director Agent 6 - Linux
Description
This connector enables hardware monitoring through the IBM Director Agent version 6.1.
Connector file name: MS_HW_Director61Linux.hdf
This connector supersedes:
Target
Typical platform: IBM xSeries
Operating system: Linux
Prerequisites
Leverages: IBM Director Agent 6.1.x
Technology and protocols: WBEM
Connector Activation Criteria
The IBM Director Agent 6 - Linux connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- Operating System is Linux
- At least one process for which the command line matches with the regular expression below is running:
cimserver
- The WBEM query below to the managed host succeeds:
- Namespace:
root/ibmsd
- WQL Query:
SELECT Version FROM IBMPSG_DirectorAgent
- Result contains:
\(^6\.1\.[2-9].*\)\|\(^6\.[2-9].*\)
(regex)
- Namespace:
- The WBEM query below to the managed host succeeds:
- Namespace:
root/ibmsd
- WQL Query:
SELECT ProductName FROM IBMPSG_ComputerSystemDetails
- Namespace:
Monitors
Object Type | Collected Parameters | Discovered Properties |
---|---|---|
Enclosure (MS_HW_ENCLOSURE ) |
|
|
Processor (MS_HW_CPU ) |
|
|
Fan (MS_HW_FAN ) |
|
|
Memory Module (MS_HW_MEMORY ) |
|
|
Power Supply (MS_HW_POWERSUPPLY ) |
|
|
Temperature Sensor (MS_HW_TEMPERATURE ) |
|
|
Voltage Sensor (MS_HW_VOLTAGE ) |
|
|
Search Results for {{siteSearch | truncate:'50'}}
{{resultArray.length}}
No results.