Back to the list of connectors
VMware ESXi 4.x
Description
This connector enables hardware monitoring for ESXi servers v4 and higher through the VMware CIM service.
Connector file name: MS_HW_VMwareESX4i.hdf
This connector is superseded by:
- MS_HW_Director5Linux.hdf
- MS_HW_Director52Linux.hdf
- MS_HW_Director61Linux.hdf
- MS_HW_HPInsightwbem.hdf
- MS_HW_DellOpenManage.hdf
- MS_HW_CpMgServNT.hdf
- MS_HW_ServerviewWBEM.hdf
This connector supersedes:
Target
Typical platform: VMware ESXi
Operating systems: Out-of-Band, Linux
Prerequisites
Leverages: WBEM
Technology and protocols: WBEM
Connector Activation Criteria
The VMware ESXi 4.x connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- The WBEM query below to the managed host succeeds:
- Namespace:
root/cimv2
- WQL Query:
SELECT MajorVersion FROM VMware_HypervisorSoftwareIdentity
- Result contains:
^[1-9][0-9]\|[4-9]
(regex)
- Namespace:
Monitors
Object Type | Collected Parameters | Discovered Properties |
---|---|---|
Enclosure (MS_HW_ENCLOSURE ) |
|
|
Battery (MS_HW_BATTERY ) |
|
|
Processor (MS_HW_CPU ) |
|
|
Fan (MS_HW_FAN ) |
|
|
Memory Module (MS_HW_MEMORY ) |
|
|
Network Card, FC Port (MS_HW_NETWORK ) |
|
|
Power Supply (MS_HW_POWERSUPPLY ) |
|
|
Temperature Sensor (MS_HW_TEMPERATURE ) |
|
|
Voltage Sensor (MS_HW_VOLTAGE ) |
|
|