Back to the list of connectors

Data Domain Storage Appliance (SNMP)

Description

This connector discovers the enclosure and the disks of Data Domain disk arrays as well as various environment sensors (temperatures, fans, power supplies). It relies on the SNMP protocol.

Connector file name: MS_HW_DataDomain.hdf

Target

Typical platform: Data Domain

Operating system: Storage System

Prerequisites

Leverages: Data Domain SNMP Agent

Technology and protocols: SNMP

This connector is not available for the local host (it is applicable to remote hosts only).

Connector Activation Criteria

The Data Domain Storage Appliance (SNMP) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.19746.1 must return a value in the same subtree

Monitors

Object Type Collected Parameters Discovered Properties
Enclosure (MS_HW_ENCLOSURE)
  • Type
  • Vendor
Battery (MS_HW_BATTERY)
  • Charge
  • Status
    Fan (MS_HW_FAN)
    • Status
    • Fan Type/Location
    Logical Disk, RAID (MS_HW_LOGICALDISK)
    • Unallocated Space
    • Size
    Physical Disk (MS_HW_PHYSICALDISK)
    • Status
    • Model
    • Serial Number
    • Size
    Power Supply (MS_HW_POWERSUPPLY)
    • Status
    • Power Supply Type
    Temperature Sensor (MS_HW_TEMPERATURE)
    • Temperature
    • Sensor Type/Location
    • Warning Threshold
    No results.