Back to the list of connectors

Aruba (SNMP)

Description

This connector discovers the Aruba Network Switch enclosure as well as various environment sensors (temperature, fans, power supplies). It relies on the SNMP protocol.

Connector file name: MS_HW_Aruba.hdf

This connector supersedes:

Target

Typical platform: Aruba

Operating system: Network Device

Prerequisites

Leverages: SNMP Agent

Technology and protocols: SNMP

Connector Activation Criteria

The Aruba (SNMP) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.2.1.2.2.1 must return a value in the same subtree
  • An SNMP Get-Next on the OID 1.3.6.1.4.1.14823.2.2.1.2 must return a value in the same subtree

Monitors

Object Type Collected Parameters Discovered Properties
Enclosure (MS_HW_ENCLOSURE)
  • Device Hostname
  • Model
  • Type
  • Vendor
Fan (MS_HW_FAN)
  • Status
    Network Card, FC Port (MS_HW_NETWORK)
    • Bandwidth Utilization
    • Error Percent
    • Link Speed
    • Link Status
    • Received Bytes Rate
    • Received Packets Rate
    • Status
    • Transmitted Bytes Rate
    • Transmitted Packets Rate
    • Device Type
    • Physical Address
    • Physical Address Type
    Power Supply (MS_HW_POWERSUPPLY)
    • Status
      Temperature Sensor (MS_HW_TEMPERATURE)
      • Status
      • Temperature
        No results.