Dell Compellent Storage Center

Description

This connector discovers the enclosures and their related controllers with the monitored Storage Controller. Dell Compellent Controller REST API Version 7 or higher is required. When configuring the HTTP protocol, the port needs to match the port configured on the host's side and the hostname/IP needs to point towards the storage controller.

Connector file name: MS_HW_DellCompellent.hdf

Target

Typical platform: Dell Compellent

Operating system: Storage System

Prerequisites

Leverages: Dell Compellent Controller REST API

Technology and protocols: HTTP/REST

This connector is not available for the local host (it is applicable to remote hosts only).

Connector Activation Criteria

The Dell Compellent Storage Center connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • The HTTP Request below to the managed host succeeds:
    • POST /api/rest/ApiConnection/Login
    • Request Header:
      EmbeddedFile(1)
    • The response body contains: sessionKey (regex)
  • The HTTP Request below to the managed host succeeds:
    • POST /api/rest/ApiConnection/Login
    • Request Header:
      EmbeddedFile(1)
    • The response body contains: StorageCenter (regex)

Monitors

Object Type Collected Parameters Discovered Properties
Enclosure (MS_HW_ENCLOSURE)
  • Status
  • Device Hostname
  • Model
  • Serial Number
  • Type
  • Vendor
Battery (MS_HW_BATTERY)
  • Status
  • Time Left
    Blade (MS_HW_BLADE)
    • Status
    • Additional Information 1
    • Blade Model
    • Serial Number
    Fan (MS_HW_FAN)
    • Speed
    • Status
    • Alarm Threshold
    • Warning Threshold
    Network Card, FC Port (MS_HW_NETWORK)
    • Link Speed
    • Link Status
    • Status
    • Device Type
    • Model
    • Physical Address
    • Physical Address Type
    Other Device (MS_HW_OTHERDEVICE)
    • Status
    • Device Type
    Physical Disk (MS_HW_PHYSICALDISK)
    • Status
    • Model
    • Serial Number
    • Size
    • Vendor
    Power Supply (MS_HW_POWERSUPPLY)
    • Status
      Temperature Sensor (MS_HW_TEMPERATURE)
      • Temperature
      • Alarm Threshold
      • Sensor Type/Location
      • Warning Threshold
      Voltage Sensor (MS_HW_VOLTAGE)
      • Status
      • Voltage
      • Lower Threshold
      • Upper Threshold
      No results.