Back to the list of connectors

Brocade SAN Switch

Description

This connector discovers the enclosure and fiber-channel ports of SAN switches as well as various environment sensors (temperatures, fans, power supplies, etc.). It relies on the SNMP protocol and supports the Brocade MIB (fcSwitch-MIB).

Connector file name: MS_HW_BrocadeSwitch.hdf

This connector is superseded by:

This connector supersedes:

Target

Typical platform: Brocade SAN

Operating system: Storage System

Prerequisites

Leverages: Brocade SNMP Agent (fcSwitch)

Technology and protocols: SNMP

Connector Activation Criteria

The Brocade SAN Switch connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.1588.2.1.1.1.1 must return a value in the same subtree

Monitors

Object Type Collected Parameters Discovered Properties
Enclosure (MS_HW_ENCLOSURE)
  • Model
  • Serial Number
  • Type
  • Vendor
Fan (MS_HW_FAN)
  • Speed
  • Status
  • Fan Type/Location
Network Card, FC Port (MS_HW_NETWORK)
  • Bandwidth Utilization
  • Duplex Mode
  • Error Percent
  • Link Speed
  • Link Status
  • Received Bytes Rate
  • Received Packets Rate
  • Status
  • Transmitted Bytes Rate
  • Transmitted Packets Rate
  • Additional Information 1
  • Additional Information 2
  • Additional Information 3
  • Bandwidth
  • Device Type
  • Physical Address
  • Physical Address Type
Other Device (MS_HW_OTHERDEVICE)
  • Status
  • Additional Information 1
  • Device Type
Power Supply (MS_HW_POWERSUPPLY)
  • Status
  • Power Supply Type
Temperature Sensor (MS_HW_TEMPERATURE)
  • Status
  • Temperature
  • Sensor Type/Location
No results.