Back to the list of connectors
EMC SMI-S Agent (ECOM)
Description
This connector discovers the enclosure and the disks of EMC SAN disk arrays, as well as the storage pools and storage volumes. It also discovers and monitors the FC ports of the array and various environment sensors when available (temperatures, fans, power supplies, etc.). It relies on the WBEM technology and supports SMI-S compliant disk arrays only.
Connector file name: MS_HW_EMCDiskArray.hdf
This connector supersedes:
Target
Typical platforms: EMC Symmetrix, EMC VMAX, EMC CLARiiON, EMC VNX
Operating system: Storage System
Prerequisites
Leverages: EMC SMI-S Agent (ECOM)
Technology and protocols: WBEM
Connector Activation Criteria
The EMC SMI-S Agent (ECOM) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- The WBEM query below to the managed host succeeds:
- Namespace:
root/emc
- WQL Query:
SELECT Name,Dedicated FROM EMC_StorageSystem
- Namespace:
- The WBEM query below to the managed host succeeds:
- Namespace:
root/emc
- WQL Query:
SELECT DeviceID FROM EMC_DiskDrive
- Namespace:
Monitors
Object Type | Collected Parameters | Discovered Properties |
---|---|---|
Enclosure (MS_HW_ENCLOSURE ) |
|
|
Battery (MS_HW_BATTERY ) |
|
|
Fan (MS_HW_FAN ) |
|
|
Network Card, FC Port (MS_HW_NETWORK ) |
|
|
Other Device (MS_HW_OTHERDEVICE ) |
|
|
Physical Disk (MS_HW_PHYSICALDISK ) |
|
|
Power Supply (MS_HW_POWERSUPPLY ) |
|
|