Hitachi Storage Command Suite SMI-S Agent

Description

This connector discovers the enclosure and the disks of Hitachi SAN disk arrays, as well as the storage pools and storage volumes. It also discovers and monitors the FC ports of the array and various environment sensors when available (temperatures, fans, power supplies, etc.). It relies on the WBEM technology and supports SMI-S compliant disk arrays only.

Connector file name: MS_HW_HitachiDiskArray.hdf

This connector is superseded by:

This connector supersedes:

Target

Typical platforms: Hitachi AMS, Hitachi HUS, Hitachi USP, Hitachi VSP

Operating system: Storage System

Prerequisites

Leverages: Hitachi Storage Command Suite SMI-S Agent

Technology and protocols: WBEM

Connector Activation Criteria

The Hitachi Storage Command Suite SMI-S Agent connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • The WBEM query below to the managed host succeeds:
    • Namespace: root/smis/current
    • WQL Query: SELECT Name,Dedicated FROM HITACHI_StorageSystem
  • The WBEM query below to the managed host succeeds:
    • Namespace: root/smis/current
    • WQL Query: SELECT DeviceID FROM HITACHI_DiskDrive

Monitors

Object Type Collected Parameters Discovered Properties
Enclosure (MS_HW_ENCLOSURE)
  • Status
  • Device Hostname
  • Model
  • Serial Number
  • Type
  • Vendor
Battery (MS_HW_BATTERY)
  • Status
    Fan (MS_HW_FAN)
    • Status
      Logical Disk, RAID (MS_HW_LOGICALDISK)
      • Status
      • RAID Level
      • Size
      Memory Module (MS_HW_MEMORY)
      • Status
        Network Card, FC Port (MS_HW_NETWORK)
        • Link Speed
        • Link Status
        • Status
        • Additional Information 1
        • Additional Information 2
        • Bandwidth
        • Device Type
        • Physical Address
        • Physical Address Type
        Other Device (MS_HW_OTHERDEVICE)
        • Status
        • Device Type
        Physical Disk (MS_HW_PHYSICALDISK)
        • Status
        • Model
        • Serial Number
        • Size
        • Vendor
        Power Supply (MS_HW_POWERSUPPLY)
        • Status