Back to the list of connectors
Hitachi Storage Command Suite SMI-S Agent
Description
This connector discovers the enclosure and the disks of Hitachi SAN disk arrays, as well as the storage pools and storage volumes. It also discovers and monitors the FC ports of the array and various environment sensors when available (temperatures, fans, power supplies, etc.). It relies on the WBEM technology and supports SMI-S compliant disk arrays only.
Connector file name: MS_HW_HitachiDiskArray.hdf
This connector is superseded by:
This connector supersedes:
Target
Typical platforms: Hitachi AMS, Hitachi HUS, Hitachi USP, Hitachi VSP
Operating system: Storage System
Prerequisites
Leverages: Hitachi Storage Command Suite SMI-S Agent
Technology and protocols: WBEM
Connector Activation Criteria
The Hitachi Storage Command Suite SMI-S Agent connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- The WBEM query below to the managed host succeeds:
- Namespace:
root/smis/current
- WQL Query:
SELECT Name,Dedicated FROM HITACHI_StorageSystem
- Namespace:
- The WBEM query below to the managed host succeeds:
- Namespace:
root/smis/current
- WQL Query:
SELECT DeviceID FROM HITACHI_DiskDrive
- Namespace:
Monitors
Object Type | Collected Parameters | Discovered Properties |
---|---|---|
Enclosure (MS_HW_ENCLOSURE ) |
|
|
Battery (MS_HW_BATTERY ) |
|
|
Fan (MS_HW_FAN ) |
|
|
Logical Disk, RAID (MS_HW_LOGICALDISK ) |
|
|
Memory Module (MS_HW_MEMORY ) |
|
|
Network Card, FC Port (MS_HW_NETWORK ) |
|
|
Other Device (MS_HW_OTHERDEVICE ) |
|
|
Physical Disk (MS_HW_PHYSICALDISK ) |
|
|
Power Supply (MS_HW_POWERSUPPLY ) |
|
|