Back to the list of connectors
HP-UX - Smart Array RAID
Description
This connector discovers and collects hardware data the physical disks connected to a Smart Array controller and any configured logical drive and spare drive.
Connector file name: MS_HW_HPUXSAUtil.hdf
This connector is superseded by:
Target
Typical platforms: HP 9000, HP Integrity, HP SuperDome
Operating system: HP-UX
Prerequisites
Leverages: HP-UX Smart Array Configuration Utility
Technology and protocols: System Commands
This connector requires advanced privileges on the managed host for the command below:
/opt/raidsa/bin/sautil
This connector therefore needs to run as root or you need to configure a privilege-escalation mechanism like sudo
on the managed host to allow the monitoring account to run the command listed above.
Sample of /etc/sudoers to allow the above command to be run as root by the patrol account:
patrol ALL=(root) NOPASSWD: /opt/raidsa/bin/sautil
Connector Activation Criteria
The HP-UX - Smart Array RAID connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- Operating System is HP-UX
- The command below succeeds on the monitored host
- Command:
ls /opt/raidsa/bin/sautil
- Output contains:
sautil$
(regex)
- Command:
- The command below succeeds on the monitored host
- Command:
/bin/sh %EmbeddedFile(1)%
- Output contains:
[GgTtMm][Bb]
(regex)
- Command:
Monitors
Object Type | Collected Parameters | Discovered Properties |
---|---|---|
Disk Controller (MS_HW_DISKCONTROLLER ) |
|
|
Battery (MS_HW_BATTERY ) |
|
|
Logical Disk, RAID (MS_HW_LOGICALDISK ) |
|
|
Physical Disk (MS_HW_PHYSICALDISK ) |
|
|