Back to the list of connectors

HP-UX (WBEM)

Description

This connector enables hardware monitoring for HP-UX servers through the HP-UX WBEM provider.

Connector file name: MS_HW_HPUXWBEM.hdf

This connector supersedes:

Target

Typical platforms: HP 9000, HP Integrity, HP SuperDome

Operating system: HP-UX

Prerequisites

Leverages: HP-UX WBEM Provider

Technology and protocols: WBEM

Connector Activation Criteria

The HP-UX (WBEM) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • The WBEM query below to the managed host succeeds:
    • Namespace: root/cimv2
    • WQL Query: SELECT DeviceID FROM HPUX_Processor

Monitors

Object Type Collected Parameters Discovered Properties
Enclosure (MS_HW_ENCLOSURE)
  • Model
  • Serial Number
  • Type
  • Vendor
Disk Controller (MS_HW_DISKCONTROLLER)
  • Controller Status
  • Status
  • Model
Processor (MS_HW_CPU)
  • Current Speed
  • Status
  • Maximum Speed
  • Model
Fan (MS_HW_FAN)
  • Status
  • Additional Information 1
Logical Disk, RAID (MS_HW_LOGICALDISK)
  • Status
    Memory Module (MS_HW_MEMORY)
    • Status
    • Additional Information 1
    • Model
    • Size
    Physical Disk (MS_HW_PHYSICALDISK)
    • Status
    • Model
    • Serial Number
    • Size
    • Vendor
    Power Supply (MS_HW_POWERSUPPLY)
    • Status
    • Additional Information 1
    • Additional Information 2
    Temperature Sensor (MS_HW_TEMPERATURE)
    • Status
    • Temperature
    • Alarm Threshold
    • Warning Threshold
    Voltage Sensor (MS_HW_VOLTAGE)
    • Status
      No results.