Back to the list of connectors
Extreme Networks (SNMP)
Description
This connector discovers the Extreme Network switch enclosure as well as various environment sensors (temperatures, fans, power supplies). It relies on the SNMP protocol.
Connector file name: MS_HW_ExtremeNetworks.hdf
This connector supersedes:
Target
Typical platform: Extreme
Operating system: Network Device
Prerequisites
Leverages: SNMP Agent
Technology and protocols: SNMP
This connector is not available for the local host (it is applicable to remote hosts only).
Connector Activation Criteria
The Extreme Networks (SNMP) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- An SNMP Get-Next on the OID
1.3.6.1.2.1.2.2.1
must return a value in the same subtree - An SNMP Get-Next on the OID
1.3.6.1.4.1.1916.1
must return a value in the same subtree
Monitors
Object Type | Collected Parameters | Discovered Properties |
---|---|---|
Enclosure (MS_HW_ENCLOSURE ) |
|
|
Fan (MS_HW_FAN ) |
|
|
Network Card, FC Port (MS_HW_NETWORK ) |
|
|
Power Supply (MS_HW_POWERSUPPLY ) |
|
|
Temperature Sensor (MS_HW_TEMPERATURE ) |
|
|