Back to the list of connectors

Cisco Entity Sensor (SNMP)

Description

This connector discovers the enclosure Cisco Ethernet switches as well as the various environment sensors (temperatures, fans, power supplies, etc.). It relies on the SNMP protocol.

Connector file name: MS_HW_CiscoEntitySensor.hdf

This connector supersedes:

Target

Typical platform: Cisco

Operating system: Network Device

Prerequisites

Leverages: Cisco SNMP Agent (ciscoMgmt)

Technology and protocols: SNMP

Connector Activation Criteria

The Cisco Entity Sensor (SNMP) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.2.1.2.2.1 must return a value in the same subtree
  • An SNMP Get-Next on the OID 1.3.6.1.4.1.9.9.91.1.1.1.1 must return a value in the same subtree
  • An SNMP Get-Next on the OID 1.3.6.1.2.1.47.1.1.1.1 must return a value in the same subtree

Monitors

Object Type Collected Parameters Discovered Properties
Enclosure (MS_HW_ENCLOSURE)
  • Power Consumption
  • Model
  • Serial Number
  • Type
  • Vendor
Fan (MS_HW_FAN)
  • Speed
  • Status
    Network Card, FC Port (MS_HW_NETWORK)
    • Bandwidth Utilization
    • Error Percent
    • Link Speed
    • Link Status
    • Received Bytes Rate
    • Received Packets Rate
    • Status
    • Transmitted Bytes Rate
    • Transmitted Packets Rate
    • Device Type
    • Physical Address
    • Physical Address Type
    Power Supply (MS_HW_POWERSUPPLY)
    • Status
    • Additional Information 1
    • Additional Information 2
    • Additional Information 3
    Temperature Sensor (MS_HW_TEMPERATURE)
    • Status
    • Temperature
      Voltage Sensor (MS_HW_VOLTAGE)
      • Status
      • Voltage
      • Voltage Type
      No results.