Oracle/Sun Fire F12K/F15K/F20K/F25K (SMS)

Description

This connector provides environmental information (temperatures, fans, etc.) and boards status on Sun Fire F12K, F15K, F20K and F25K servers.

Connector file name: MS_HW_SunF15K.hdf

Target

Typical platform: Oracle/Sun Fire F15K

Operating systems: Oracle Solaris, Out-of-Band

Prerequisites

Leverages: Sun SMS utilities installed on the System Controller (SC on F15K, etc.)

Technology and protocols: System Commands

Connector Activation Criteria

The Oracle/Sun Fire F12K/F15K/F20K/F25K (SMS) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • Operating System is Oracle Solaris or Out-of-Band
  • The command below succeeds on the monitored host
    • Command: LD_LIBRARY_PATH=$LD_LIBRARY_PATH:/opt/SUNWSMS/lib;export LD_LIBRARY_PATH;PATH=$PATH:/opt/SUNWSMS/bin;export PATH;which showplatform
    • Output contains: /showplatform$ (regex)
  • The command below succeeds on the monitored host
    • Command: LD_LIBRARY_PATH=$LD_LIBRARY_PATH:/opt/SUNWSMS/lib;export LD_LIBRARY_PATH;PATH=$PATH:/opt/SUNWSMS/bin;export PATH;showplatform
    • Output contains: ^Platform Type: Sun Fire (regex)

Monitors

Object Type Collected Parameters Discovered Properties
Enclosure (MS_HW_ENCLOSURE)
  • Power Consumption
  • Model
  • Type
  • Vendor
Fan (MS_HW_FAN)
  • Status
  • Fan Type/Location
Other Device (MS_HW_OTHERDEVICE)
  • Status
  • Additional Label
  • Device Type
Power Supply (MS_HW_POWERSUPPLY)
  • Status
    Temperature Sensor (MS_HW_TEMPERATURE)
    • Status
    • Temperature
    • Sensor Type/Location
    Voltage Sensor (MS_HW_VOLTAGE)
    • Status
    • Voltage
    • Voltage Type
    No results.