Back to the list of connectors

HP iLO Gen 9 (REST)

Description

This connector discovers the status of an HPE Proliant Gen 9 system using iLO 4, as well as various environment sensors (temperatures, fans, power supplies, etc.). Requires iLO 4.

Connector file name: MS_HW_HPEGen9IloREST.hdf

This connector supersedes:

Target

Typical platform: HP iLO Gen 9 REST

Operating system: Out-of-Band

Prerequisites

Requires KM Version: 10.3.00 or greater

Leverages:

Technology and protocols: HTTP/REST

This connector is not available for the local host (it is applicable to remote hosts only).

Connector Activation Criteria

The HP iLO Gen 9 (REST) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • The KM is in version 10.3.00 or greater
  • The HTTP Request below to the managed host succeeds:
    • GET /redfish/v1/
    • Request Header:
      EmbeddedFile(1)
    • The response body contains: iLO 4 (regex)

Monitors

Object Type Collected Parameters Discovered Properties
Enclosure (MS_HW_ENCLOSURE)
  • Power Consumption
  • Power State
  • Status
  • Model
  • Serial Number
  • Type
  • Vendor
Disk Controller (MS_HW_DISKCONTROLLER)
  • Controller Status
  • Status
  • Firmware Version
  • Model
  • Serial Number
Battery (MS_HW_BATTERY)
  • Status
  • Additional Information 1
  • Additional Information 2
  • Model
Processor (MS_HW_CPU)
  • Status
  • Maximum Speed
  • Model
  • Vendor
Fan (MS_HW_FAN)
  • Speed Percent
  • Status
  • Additional Information 1
Logical Disk, RAID (MS_HW_LOGICALDISK)
  • Status
  • RAID Level
  • Size
Memory Module (MS_HW_MEMORY)
  • Status
  • Model
  • Serial Number
  • Size
  • Vendor
Network Card, FC Port (MS_HW_NETWORK)
  • Link Speed
  • Link Status
  • Status
  • Model
  • Physical Address
  • Serial Number
Physical Disk (MS_HW_PHYSICALDISK)
  • Endurance Remaining
  • Status
  • Additional Information 1
  • Firmware Version
  • Model
  • Serial Number
  • Size
Power Supply (MS_HW_POWERSUPPLY)
  • Status
  • Additional Information 1
  • Additional Information 2
  • Additional Information 3
  • Power (Nominal)
  • Power Supply Type
Temperature Sensor (MS_HW_TEMPERATURE)
  • Status
  • Temperature
  • Additional Information 1
  • Alarm Threshold
  • Warning Threshold
No results.