Back to the list of connectors
MegaCLI Managed RAID Controllers
Description
This connector enables hardware monitoring for LSI RAID controllers in Oracle/Sun Solaris systems, and in IBM servers with EXP3000 external bays. This connector relies on MegaCli.
Connector file name: MS_HW_SunMegaCli.hdf
This connector supersedes:
Target
Typical platform: Any system with LSI MegaCli
Operating systems: Oracle Solaris, Linux
Prerequisites
Leverages: MegaCli (LSI) managed RAID card
Technology and protocols: System Commands
This connector requires advanced privileges on the managed host for the command below:
MegaCli
This connector therefore needs to run as root or you need to configure a privilege-escalation mechanism like sudo
on the managed host to allow the monitoring account to run the command listed above.
Sample of /etc/sudoers to allow the above command to be run as root by the patrol account:
patrol ALL=(root) NOPASSWD: MegaCli
Connector Activation Criteria
The MegaCLI Managed RAID Controllers connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- Operating System is Oracle Solaris or Linux
- The command below succeeds on the monitored host
- Command:
MegaCli -v -NoLog
- Output contains:
Exit Code: 0x00
(regex)
- Command:
- The command below succeeds on the monitored host
- Command:
MegaCli -AdpAllInfo -aALL -NoLog
- Output contains:
Exit Code: 0x00
(regex)
- Command:
- The command below succeeds on the monitored host
- Command:
MegaCli -PDList -aALL -NoLog
- Output contains:
Exit Code: 0x00
(regex)
- Command:
Monitors
Object Type | Collected Parameters | Discovered Properties |
---|---|---|
Disk Controller (MS_HW_DISKCONTROLLER ) |
|
|
Battery (MS_HW_BATTERY ) |
|
|
Logical Disk, RAID (MS_HW_LOGICALDISK ) |
|
|
Physical Disk (MS_HW_PHYSICALDISK ) |
|
|