Back to the list of connectors

Quantum (ADIC) Enterprise Level Tape Libraries

Description

This connector enables hardware monitoring for i2000 and i6000 libraries through the Quantum Scalar's SNMP interface.

Connector file name: MS_HW_QuantumTapeLibraryi6000.hdf

This connector supersedes:

Target

Typical platforms: Quantum Scalar i2000, Quantum Scalar i6000

Operating system: Storage System

Prerequisites

Leverages: Quantum SNMP Agent (ADIC-MANAGEMENT-MIB)

Technology and protocols: SNMP

This connector is not available for the local host (it is applicable to remote hosts only).

Connector Activation Criteria

The Quantum (ADIC) Enterprise Level Tape Libraries connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.3764.1.1.200.20.80.110.1 must return a value in the same subtree

Monitors

Object Type Collected Parameters Discovered Properties
Enclosure (MS_HW_ENCLOSURE)
  • Status
  • Additional Information 1
  • BIOS Version
  • Model
  • Serial Number
  • Type
  • Vendor
Fan (MS_HW_FAN)
  • Speed
  • Status
  • Alarm Threshold
  • Warning Threshold
Other Device (MS_HW_OTHERDEVICE)
  • Status
  • Device Type
Power Supply (MS_HW_POWERSUPPLY)
  • Status
    Robotic (MS_HW_ROBOTICS)
    • Status
      Tape Drive (MS_HW_TAPEDRIVE)
      • Error Count
      • Mount Count
      • Needs Cleaning
      • Status
      • Additional Information 1
      • Model
      • Serial Number
      • Vendor
      Temperature Sensor (MS_HW_TEMPERATURE)
      • Status
      • Temperature
      • Alarm Threshold
      • Warning Threshold
      Voltage Sensor (MS_HW_VOLTAGE)
      • Status
      • Voltage
      • Lower Threshold
      • Upper Threshold
      No results.