Back to the list of connectors
Quanta Rack Mount Server Unit
Description
This connector enables hardware monitoring for the Quanta Rack Mount Server Unit through the SNMP Agent of Quanta System Manager. As Quanta System Manager is an application exposing data about other systems, this connector needs to be configured for a separate "Management Card/Chip" host, even if the Quanta System Manager is installed on the same system as the agent.
Connector file name: MS_HW_Quanta.hdf
Target
Typical platform: Quanta Server
Operating system: Out-of-Band
Prerequisites
Leverages: Quanta System Manager SNMP Agent
Technology and protocols: SNMP
This connector is not available for the local host (it is applicable to remote hosts only).
Connector Activation Criteria
The Quanta Rack Mount Server Unit connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- An SNMP Get-Next on the OID
1.3.6.1.4.1.7244.1.2.1.3.1.1.3
must return a value in the same subtree
Monitors
Object Type | Collected Parameters | Discovered Properties |
---|---|---|
Enclosure (MS_HW_ENCLOSURE ) |
|
|
Processor (MS_HW_CPU ) |
|
|
Fan (MS_HW_FAN ) |
|
|
Memory Module (MS_HW_MEMORY ) |
|
|
Power Supply (MS_HW_POWERSUPPLY ) |
|
|
Temperature Sensor (MS_HW_TEMPERATURE ) |
|
|
Voltage Sensor (MS_HW_VOLTAGE ) |
|
|