Back to the list of connectors

Oracle/Sun Enterprise Mx000 (XSCF)

Description

This connector provides environmental information (temperatures, fans, etc.) and boards status on SPARC Enterprise M4000, M5000, M8000 and M9000 servers.

Connector file name: MS_HW_SunXscf.hdf

Target

Typical platform: Oracle/Sun Enterprise Mx000

Operating systems: Oracle Solaris, Out-of-Band

Prerequisites

Leverages: Sun XSCF utilities installed on the System Controller

Technology and protocols: System Commands

This connector is not available for the local host (it is applicable to remote hosts only).

Connector Activation Criteria

The Oracle/Sun Enterprise Mx000 (XSCF) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • The command below succeeds on the monitored host
    • Command: showhardconf
    • Output contains: Serial: (regex)

Monitors

Object Type Collected Parameters Discovered Properties
Enclosure (MS_HW_ENCLOSURE)
  • Status
  • Additional Information 1
  • Model
  • Serial Number
  • Type
  • Vendor
Processor (MS_HW_CPU)
  • Status
  • Additional Information 1
  • Additional Information 2
  • Maximum Speed
  • Model
Fan (MS_HW_FAN)
  • Status
  • Fan Type/Location
Memory Module (MS_HW_MEMORY)
  • Status
  • Serial Number
  • Size
  • Type
Other Device (MS_HW_OTHERDEVICE)
  • Power Consumption
  • Status
  • Additional Information 1
  • Additional Information 2
  • Additional Label
  • Device Type
Power Supply (MS_HW_POWERSUPPLY)
  • Status
  • Additional Information 1
  • Additional Information 2
Temperature Sensor (MS_HW_TEMPERATURE)
  • Temperature
  • Alarm Threshold
  • Sensor Type/Location
  • Warning Threshold
Voltage Sensor (MS_HW_VOLTAGE)
  • Voltage
  • Lower Threshold
  • Upper Threshold
  • Voltage Type
No results.