Back to the list of connectors

IBM AIX - Environment (uesensor)

Description

This connector provides hardware environment information on IBM AIX systems (temperature sensors, voltage sensors, fans, power supplies).

Connector file name: MS_HW_IBMAIXUeSensor.hdf

This connector is superseded by:

Target

Typical platform: IBM POWER

Operating system: IBM AIX

Prerequisites

Leverages: IBM AIX system commands (uesensor)

Technology and protocols: System Commands

Connector Activation Criteria

The IBM AIX - Environment (uesensor) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • Operating System is IBM AIX
  • The command below succeeds on the monitored host
    • Command: /bin/ls /usr/lpp/diagnostics/bin/uesensor
    • Output contains: ^/usr/lpp/diagnostics/bin/uesensor$ (regex)
  • The command below succeeds on the monitored host
    • Command: /usr/lpp/diagnostics/bin/uesensor -a
    • Output contains: ^3 \|^9001 \|^9002 \|^9004 (regex)

Monitors

Object Type Collected Parameters Discovered Properties
Fan (MS_HW_FAN)
  • Speed
  • Alarm Threshold
  • Fan Type/Location
  • Warning Threshold
Power Supply (MS_HW_POWERSUPPLY)
  • Status
  • Power Supply Type
Temperature Sensor (MS_HW_TEMPERATURE)
  • Temperature
  • Alarm Threshold
  • Sensor Type/Location
  • Warning Threshold
Voltage Sensor (MS_HW_VOLTAGE)
  • Status
  • Voltage
  • Voltage Type
No results.