Back to the list of connectors
IBM AIX - Environment (uesensor)
Description
This connector provides hardware environment information on IBM AIX systems (temperature sensors, voltage sensors, fans, power supplies).
Connector file name: MS_HW_IBMAIXUeSensor.hdf
This connector is superseded by:
Target
Typical platform: IBM POWER
Operating system: IBM AIX
Prerequisites
Leverages: IBM AIX system commands (uesensor)
Technology and protocols: System Commands
Connector Activation Criteria
The IBM AIX - Environment (uesensor) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- Operating System is IBM AIX
- The command below succeeds on the monitored host
- Command:
/bin/ls /usr/lpp/diagnostics/bin/uesensor
- Output contains:
^/usr/lpp/diagnostics/bin/uesensor$
(regex)
- Command:
- The command below succeeds on the monitored host
- Command:
/usr/lpp/diagnostics/bin/uesensor -a
- Output contains:
^3 \|^9001 \|^9002 \|^9004
(regex)
- Command:
Monitors
Object Type | Collected Parameters | Discovered Properties |
---|---|---|
Fan (MS_HW_FAN ) |
|
|
Power Supply (MS_HW_POWERSUPPLY ) |
|
|
Temperature Sensor (MS_HW_TEMPERATURE ) |
|
|
Voltage Sensor (MS_HW_VOLTAGE ) |
|
|
Search Results for {{siteSearch | truncate:'50'}}
{{resultArray.length}}