Back to the list of connectors
IBM AIX - sissasraidmgr Disk Controllers
Description
This connector enables hardware monitoring for RAID controllers in IBM AIX servers through the syssasraidmgr command line utility.
Connector file name: MS_HW_IBMAIXSissasraidmgr.hdf
Target
Typical platform: IBM POWER
Operating system: IBM AIX
Prerequisites
Leverages: sissasraidmgr managed RAID card
Technology and protocols: System Commands
This connector requires advanced privileges on the managed host for the command below:
/usr/bin/sissasraidmgr
This connector therefore needs to run as root or you need to configure a privilege-escalation mechanism like sudo
on the managed host to allow the monitoring account to run the command listed above.
Sample of /etc/sudoers to allow the above command to be run as root by the patrol account:
patrol ALL=(root) NOPASSWD: /usr/bin/sissasraidmgr
Connector Activation Criteria
The IBM AIX - sissasraidmgr Disk Controllers connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- The command below succeeds on the monitored host
- Command:
cd /etc/objrepos;/usr/bin/sissasraidmgr
- Output contains:
0940-002 Invalid or no command specified
(regex)
- Command:
- The command below succeeds on the monitored host
- Command:
ls /dev/sissas*
- Output contains:
/dev/sissas[0-9]
(regex)
- Command:
- The command below succeeds on the monitored host
- Command:
for CTRL in `ls /dev/sissas* | sed s:/dev/::`;do cd /etc/objrepos; /usr/bin/sissasraidmgr -Ll $CTRL;done;
- Output contains:
hdisk[0-9]
(regex)
- Command:
Monitors
Object Type | Collected Parameters | Discovered Properties |
---|---|---|
Disk Controller (MS_HW_DISKCONTROLLER ) |
|
|
Battery (MS_HW_BATTERY ) |
|
|
Logical Disk, RAID (MS_HW_LOGICALDISK ) |
|
|
Physical Disk (MS_HW_PHYSICALDISK ) |
|
|