Back to the list of connectors

IBM AIX - sissasraidmgr Disk Controllers

Description

This connector enables hardware monitoring for RAID controllers in IBM AIX servers through the syssasraidmgr command line utility.

Connector file name: MS_HW_IBMAIXSissasraidmgr.hdf

Target

Typical platform: IBM POWER

Operating system: IBM AIX

Prerequisites

Leverages: sissasraidmgr managed RAID card

Technology and protocols: System Commands

This connector requires advanced privileges on the managed host for the command below:

  • /usr/bin/sissasraidmgr

This connector therefore needs to run as root or you need to configure a privilege-escalation mechanism like sudo on the managed host to allow the monitoring account to run the command listed above.

Sample of /etc/sudoers to allow the above command to be run as root by the patrol account:

patrol ALL=(root) NOPASSWD: /usr/bin/sissasraidmgr

Connector Activation Criteria

The IBM AIX - sissasraidmgr Disk Controllers connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • The command below succeeds on the monitored host
    • Command: cd /etc/objrepos;/usr/bin/sissasraidmgr
    • Output contains: 0940-002 Invalid or no command specified (regex)
  • The command below succeeds on the monitored host
    • Command: ls /dev/sissas*
    • Output contains: /dev/sissas[0-9] (regex)
  • The command below succeeds on the monitored host
    • Command: for CTRL in `ls /dev/sissas* | sed s:/dev/::`;do cd /etc/objrepos; /usr/bin/sissasraidmgr -Ll $CTRL;done;
    • Output contains: hdisk[0-9] (regex)

Monitors

Object Type Collected Parameters Discovered Properties
Disk Controller (MS_HW_DISKCONTROLLER)
  • Additional Information 1
  • Model
Battery (MS_HW_BATTERY)
  • Status
    Logical Disk, RAID (MS_HW_LOGICALDISK)
    • Status
    • Additional Information 1
    • Size
    Physical Disk (MS_HW_PHYSICALDISK)
    • Status
    • Additional Information 1
    • Size
    No results.