Back to the list of connectors
HP P2000 G3 or Later (WBEM)
Description
This connector discovers physical disks, logical disks, management network cards and fiber ports on P2000 G3 later Series filers through the embedded SMI-S Provider.
Connector file name: MS_HW_HPP2000WBEM.hdf
This connector supersedes:
Target
Typical platform: HP StorageWorks P2000 G3
Operating system: Storage System
Prerequisites
Leverages: HP P2000 Management Card
Technology and protocols: WBEM
This connector is not available for the local host (it is applicable to remote hosts only).
Connector Activation Criteria
The HP P2000 G3 or Later (WBEM) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- The WBEM query below to the managed host succeeds:
- Namespace:
root/hpq
- WQL Query:
SELECT Name FROM HP_TopComputerSystem
- Namespace:
- The WBEM query below to the managed host succeeds:
- Namespace:
root/hpq
- WQL Query:
SELECT Tag FROM HP_TopComputerSystemChassis
- Namespace:
Monitors
Object Type | Collected Parameters | Discovered Properties |
---|---|---|
Enclosure (MS_HW_ENCLOSURE ) |
|
|
Fan (MS_HW_FAN ) |
|
|
Logical Disk, RAID (MS_HW_LOGICALDISK ) |
|
|
Network Card, FC Port (MS_HW_NETWORK ) |
|
|
Other Device (MS_HW_OTHERDEVICE ) |
|
|
Physical Disk (MS_HW_PHYSICALDISK ) |
|
|
Power Supply (MS_HW_POWERSUPPLY ) |
|
|
Temperature Sensor (MS_HW_TEMPERATURE ) |
|
|
Voltage Sensor (MS_HW_VOLTAGE ) |
|
|