Back to the list of connectors

Fujitsu Eternus DX Disk Arrays

Description

This connector discovers the enclosure and the disks of Fujitsu SAN disk arrays, as well as the storage pools and storage volumes. It will also discover and monitor the FC ports of the array and the various environment sensors when available (temperatures, fans, power supplies, etc.). It relies on the WBEM technology and supports SMI-S compliant disk arrays only.

Connector ID: FujitsuEternus

This connector supersedes:

Target

Typical platform: Fujitsu Eternus

Operating system: Storage System

Prerequisites

Leverages: Fujitsu Eternus SMI-S Server

Technology and protocols: WBEM

Examples

CLI

hws HOSTNAME -t storage -f FujitsuEternus --wbem -u USER

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: storage
  selectedConnectors: [ FujitsuEternus ] # Optional, to load only this connector
  wbem:
    protocol: https
    port: 5989
    username: <USERNAME> # Change with actual credentials
    password: <PASSWORD> # Encrypted using hws-encrypt

Connector Activation Criteria

The Fujitsu Eternus DX Disk Arrays connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • The WBEM query below to the managed host succeeds:
    • Namespace: root/eternus
    • WQL Query: SELECT Name,Dedicated FROM FUJITSU_StorageComputerSystem

Metrics

Type Collected Metrics Specific Attributes (Labels)
Enclosure
  • hw.status{hw.type="enclosure",state="ok|degraded|failed"}
  • hw.status{hw.type="enclosure",state="present"}
  • info
  • model
  • serial_number
  • type
  • vendor
Battery
  • hw.status{hw.type="battery",state="ok|degraded|failed"}
  • hw.status{hw.type="battery",state="present"}
    Fan
    • hw.status{hw.type="fan",state="ok|degraded|failed"}
    • hw.status{hw.type="fan",state="present"}
      Logical Disk, RAID
      • hw.logical_disk.limit
      • hw.logicaldisk.utilization{state="free|used"}
      • hw.status{hw.type="logical_disk",state="ok|degraded|failed"}
      • hw.status{hw.type="logical_disk",state="present"}
      • raid_level
      Memory Module
      • hw.memory.limit
      • hw.status{hw.type="memory",state="ok|degraded|failed"}
      • hw.status{hw.type="memory",state="present"}
      • model
      Network Card, FC Port
      • hw.network.bandwidth.limit
      • hw.status{hw.type="network",state="ok|degraded|failed"}
      • hw.status{hw.type="network",state="present"}
      • info
      • physical_address
      Other Device
      • hw.status{hw.type="other_device",state="ok|degraded|failed"}
      • hw.status{hw.type="other_device",state="present"}
      • device_type
      Physical Disk
      • hw.physical_disk.size
      • hw.status{hw.type="physical_disk",state="ok|degraded|failed"}
      • hw.status{hw.type="physical_disk",state="present"}
      • info
      • firmware_version
      • model
      • serial_number
      • vendor
      Power Supply
      • hw.status{hw.type="power_supply",state="ok|degraded|failed"}
      • hw.status{hw.type="power_supply",state="present"}
        No results.