Back to the list of connectors

SMI-S Compliant Disk Arrays

Description

This connector discovers the enclosure and the disks of SAN disk arrays, as well as the storage pools and storage volumes. It will also discover and monitor the FC ports of the array and the various environment sensors when available (temperatures, fans, power supplies, etc.). It relies on the WBEM technology and supports SMI-S compliant disk arrays only.

Connector ID: SMISDiskArray

This connector is superseded by:

Target

Typical platform: Any SMI-S compliant disk array

Operating system: Storage System

Prerequisites

Leverages: SMI-S Agent provided by the array vendor

Technology and protocols: WBEM

Examples

CLI

hws HOSTNAME -t storage -f SMISDiskArray --wbem -u USER

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: storage
  selectedConnectors: [ SMISDiskArray ] # Optional, to load only this connector
  wbem:
    protocol: https
    port: 5989
    username: <USERNAME> # Change with actual credentials
    password: <PASSWORD> # Encrypted using hws-encrypt

Connector Activation Criteria

The SMI-S Compliant Disk Arrays connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • The WBEM query below to the managed host succeeds:
    • Namespace: Automatic
    • WQL Query: SELECT Name,Dedicated FROM CIM_ComputerSystem
    • Result contains: [;|]3|[0-9|]*;$ (regex)
  • The WBEM query below to the managed host succeeds:
    • Namespace: Automatic
    • WQL Query: SELECT DeviceID FROM CIM_DiskDrive

Metrics

Type Collected Metrics Specific Attributes (Labels)
Enclosure
  • hw.status{hw.type="enclosure",state="ok|degraded|failed"}
  • hw.status{hw.type="enclosure",state="present"}
  • model
  • serial_number
  • type
  • vendor
Fan
  • hw.status{hw.type="fan",state="ok|degraded|failed"}
  • hw.status{hw.type="fan",state="present"}
    Logical Disk, RAID
    • hw.logical_disk.limit
    • hw.logicaldisk.utilization{state="free|used"}
    • hw.status{hw.type="logical_disk",state="ok|degraded|failed"}
    • hw.status{hw.type="logical_disk",state="present"}
    • info
    • raid_level
    Network Card, FC Port
    • hw.network.up
    • hw.status{hw.type="network",state="ok|degraded|failed"}
    • hw.status{hw.type="network",state="present"}
    • info
    • model
    • physical_address
    • serial_number
    • vendor
    Other Device
    • hw.status{hw.type="other_device",state="ok|degraded|failed"}
    • hw.status{hw.type="other_device",state="present"}
    • info
    • device_type
    Physical Disk
    • hw.physical_disk.size
    • hw.status{hw.type="physical_disk",state="ok|degraded|failed"}
    • hw.status{hw.type="physical_disk",state="present"}
    • info
    • model
    • serial_number
    • vendor
    Power Supply
    • hw.status{hw.type="power_supply",state="ok|degraded|failed"}
    • hw.status{hw.type="power_supply",state="present"}
      Temperature Sensor
      • hw.status{hw.type="temperature",state="ok|degraded|failed"}
      • hw.status{hw.type="temperature",state="present"}
      • hw.temperature
      • hw.temperature.limit{limit_type="high.critical"}
      • hw.temperature.limit{limit_type="high.degraded"}
        No results.