Back to the list of connectors

HPE Primera / HP 3PAR Disk Array

Description

This connector discovers the enclosure and the disks of HPE Primera and HP 3PAR disk arrays, as well as the storage pools. It also discovers and monitor the FC ports of the array and the various environment sensors when available (temperatures, fans, power supplies, etc.). It relies on the WBEM technology and supports SMI-S compliant disk arrays only.

Connector ID: HP3PAR

This connector supersedes:

Target

Typical platform: HPE Primera / HP 3PAR

Operating system: Storage System

Prerequisites

Leverages: HPE Primera / HP 3PAR Embedded SMI-S Provider

Technology and protocols: WBEM

Examples

CLI

hws HOSTNAME -t storage -f HP3PAR --wbem -u USER

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: storage
  selectedConnectors: [ HP3PAR ] # Optional, to load only this connector
  wbem:
    protocol: https
    port: 5989
    username: <USERNAME> # Change with actual credentials
    password: <PASSWORD> # Encrypted using hws-encrypt

Connector Activation Criteria

The HPE Primera / HP 3PAR Disk Array connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • The WBEM query below to the managed host succeeds:
    • Namespace: root/tpd
    • WQL Query: SELECT Name FROM TPD_StorageSystem

Metrics

Type Collected Metrics Specific Attributes (Labels)
Enclosure
  • hw.status{hw.type="enclosure",state="ok|degraded|failed"}
  • hw.status{hw.type="enclosure",state="present"}
  • info
  • bios_version
  • model
  • serial_number
  • type
  • vendor
Battery
  • hw.status{hw.type="battery",state="ok|degraded|failed"}
  • hw.status{hw.type="battery",state="present"}
  • info
Blade
  • hw.status{hw.type="blade",state="ok|degraded|failed"}
  • hw.status{hw.type="blade",state="present"}
  • info
  • model
  • serial_number
Processor
  • hw.status{hw.type="cpu",state="ok|degraded|failed"}
  • hw.status{hw.type="cpu",state="present"}
  • info
Fan
  • hw.status{hw.type="fan",state="ok|degraded|failed"}
  • hw.status{hw.type="fan",state="present"}
  • info
Logical Disk, RAID
  • hw.logical_disk.limit
  • hw.status{hw.type="logical_disk",state="ok|degraded|failed"}
  • hw.status{hw.type="logical_disk",state="present"}
  • raid_level
Memory Module
  • hw.memory.limit
  • hw.status{hw.type="memory",state="ok|degraded|failed"}
  • hw.status{hw.type="memory",state="present"}
  • info
  • model
  • serial_number
  • vendor
Network Card, FC Port
  • hw.errors{hw.type="network"}
  • hw.network.io{direction="receive"}
  • hw.network.io{direction="transmit"}
  • hw.network.packets{direction="receive"}
  • hw.network.packets{direction="transmit"}
  • hw.status{hw.type="network",state="ok|degraded|failed"}
  • hw.status{hw.type="network",state="present"}
  • physical_address
Other Device
  • hw.status{hw.type="other_device",state="ok|degraded|failed"}
  • hw.status{hw.type="other_device",state="present"}
  • info
  • device_type
Physical Disk
  • hw.physical_disk.size
  • hw.status{hw.type="physical_disk",state="ok|degraded|failed"}
  • hw.status{hw.type="physical_disk",state="present"}
  • info
  • model
  • serial_number
  • vendor
Power Supply
  • hw.status{hw.type="power_supply",state="ok|degraded|failed"}
  • hw.status{hw.type="power_supply",state="present"}
  • info
Temperature Sensor
  • hw.status{hw.type="temperature",state="present"}
  • hw.temperature
  • hw.temperature.limit{limit_type="high.critical"}
  • hw.temperature.limit{limit_type="high.degraded"}
    Voltage Sensor
    • hw.status{hw.type="voltage",state="present"}
    • hw.voltage
    • hw.voltage.limit{limit_type="high.critical"}
    • hw.voltage.limit{limit_type="low.critical"}