Back to the list of connectors
Hitachi HDS USP/VSP (SNMP)
Description
This connector discovers the overall (global) status of Hitachi USP/VSP's Processors, CSW, Cache, SM, Power Supplies, Batteries, Fans, Physical Disks and Environment.
Connector ID: HitachiVSPSNMP
This connector is superseded by:
This connector supersedes:
Target
Typical platforms: Hitachi USP, Hitachi VSP
Operating system: Storage System
Prerequisites
Leverages: Hitachi SNMP Agent
Technology and protocols: SNMP
Examples
CLI
hws HOSTNAME -t storage -f HitachiVSPSNMP --snmp v2c --community public
hws-config.yaml
hosts:
- host:
hostname: <HOSTNAME> # Change with actual host name
type: storage
selectedConnectors: [ HitachiVSPSNMP ] # Optional, to load only this connector
snmp:
version: v1 # Read documentation for v2 and v3
community: public # or probably something more secure
Connector Activation Criteria
The Hitachi HDS USP/VSP (SNMP) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- An SNMP Get-Next on the OID
1.3.6.1.4.1.116.5.11.4.1.1.6.1
must return a value in the same subtree
Metrics
Type | Collected Metrics | Specific Attributes (Labels) |
---|---|---|
Enclosure |
|
|
Battery |
|
|
Processor |
|
|
Fan |
|
|
Memory Module |
|
|
Other Device |
|
|
Physical Disk |
|
|
Power Supply |
|
|
Temperature Sensor |
|
|